    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot S90 / prf-academy-rawtoaces-canon-powershot-s90-30da0d87505d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot S90 / prf-academy-rawtoaces-canon-powershot-s90-30da0d87505d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Weta lightsaber rig (44 records); SciTech legacy (7 records, no equipment named); NPL double monochromator (1 record).; source=Weta Digital; Academy / Weta RAWtoaces camera JSON bundle; src-academy-rawtoaces-weta-bundle; Academy Software Foundation, rawtoaces-data, pinned revision e9b8503cf8a0641f40e5345d9757bde60c15f423, 2025.; https://github.com/AcademySoftwareFoundation/rawtoaces-data Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-780,green:380-780,blue:380-780. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755,
        760,
        765,
        770,
        775,
        780
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0126,
        0.0117,
        0.0107,
        0.0089,
        0.007,
        0.0119,
        0.0168,
        0.0282,
        0.0397,
        0.0364,
        0.0331,
        0.0323,
        0.0316,
        0.03,
        0.0284,
        0.0277,
        0.027,
        0.0306,
        0.0342,
        0.0363,
        0.0383,
        0.0368,
        0.0353,
        0.0377,
        0.0401,
        0.0462,
        0.0523,
        0.0682,
        0.0841,
        0.0888,
        0.0935,
        0.0748,
        0.0562,
        0.048,
        0.0398,
        0.0388,
        0.0377,
        0.0577,
        0.0778,
        0.3061,
        0.5344,
        0.6576,
        0.7808,
        0.7927,
        0.8046,
        0.7924,
        0.7802,
        0.7689,
        0.7575,
        0.7442,
        0.7308,
        0.7092,
        0.6875,
        0.6593,
        0.631,
        0.5509,
        0.4709,
        0.2849,
        0.0988,
        0.0602,
        0.0217,
        0.0172,
        0.0127,
        0.009,
        0.0053,
        0.0044,
        0.0036,
        0.0042,
        0.0048,
        0.0042,
        0.0036,
        0.003,
        0.0024,
        0.0018,
        0.0012,
        0.0013,
        0.0013,
        0.0014,
        0.0015,
        0.0016,
        0.0017
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot S90 / prf-academy-rawtoaces-canon-powershot-s90-30da0d87505d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot S90 / prf-academy-rawtoaces-canon-powershot-s90-30da0d87505d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Weta lightsaber rig (44 records); SciTech legacy (7 records, no equipment named); NPL double monochromator (1 record).; source=Weta Digital; Academy / Weta RAWtoaces camera JSON bundle; src-academy-rawtoaces-weta-bundle; Academy Software Foundation, rawtoaces-data, pinned revision e9b8503cf8a0641f40e5345d9757bde60c15f423, 2025.; https://github.com/AcademySoftwareFoundation/rawtoaces-data Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-780,green:380-780,blue:380-780. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755,
        760,
        765,
        770,
        775,
        780
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0237,
        0.0199,
        0.0161,
        0.0156,
        0.0152,
        0.0249,
        0.0347,
        0.0661,
        0.0975,
        0.1055,
        0.1135,
        0.1327,
        0.152,
        0.1784,
        0.2048,
        0.2441,
        0.2834,
        0.3405,
        0.3976,
        0.4353,
        0.473,
        0.4849,
        0.4968,
        0.5697,
        0.6426,
        0.7061,
        0.7697,
        0.8313,
        0.8929,
        0.9464,
        1,
        0.9597,
        0.9194,
        0.9147,
        0.9099,
        0.8743,
        0.8388,
        0.8146,
        0.7904,
        0.7439,
        0.6975,
        0.6265,
        0.5555,
        0.5005,
        0.4454,
        0.3736,
        0.3019,
        0.2598,
        0.2178,
        0.1934,
        0.1691,
        0.1543,
        0.1394,
        0.1243,
        0.1091,
        0.0965,
        0.0839,
        0.0527,
        0.0215,
        0.0144,
        0.0073,
        0.0063,
        0.0052,
        0.0049,
        0.0045,
        0.0045,
        0.0046,
        0.0044,
        0.0043,
        0.0038,
        0.0032,
        0.0027,
        0.0022,
        0.0017,
        0.0012,
        0.0013,
        0.0014,
        0.0015,
        0.0017,
        0.0018,
        0.0019
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot S90 / prf-academy-rawtoaces-canon-powershot-s90-30da0d87505d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon PowerShot S90 / prf-academy-rawtoaces-canon-powershot-s90-30da0d87505d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Weta lightsaber rig (44 records); SciTech legacy (7 records, no equipment named); NPL double monochromator (1 record).; source=Weta Digital; Academy / Weta RAWtoaces camera JSON bundle; src-academy-rawtoaces-weta-bundle; Academy Software Foundation, rawtoaces-data, pinned revision e9b8503cf8a0641f40e5345d9757bde60c15f423, 2025.; https://github.com/AcademySoftwareFoundation/rawtoaces-data Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-780,green:380-780,blue:380-780. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755,
        760,
        765,
        770,
        775,
        780
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0165,
        0.0164,
        0.0163,
        0.0152,
        0.0141,
        0.0749,
        0.1357,
        0.2702,
        0.4047,
        0.432,
        0.4592,
        0.504,
        0.5488,
        0.599,
        0.6492,
        0.675,
        0.7007,
        0.7068,
        0.7128,
        0.6715,
        0.6301,
        0.5886,
        0.5471,
        0.4714,
        0.3957,
        0.3426,
        0.2894,
        0.2343,
        0.1792,
        0.1544,
        0.1296,
        0.1084,
        0.0873,
        0.0732,
        0.0591,
        0.0462,
        0.0333,
        0.0279,
        0.0225,
        0.0195,
        0.0166,
        0.0147,
        0.0129,
        0.0121,
        0.0113,
        0.0108,
        0.0103,
        0.0104,
        0.0105,
        0.0119,
        0.0132,
        0.0154,
        0.0176,
        0.0231,
        0.0286,
        0.0281,
        0.0276,
        0.0175,
        0.0075,
        0.0058,
        0.004,
        0.0035,
        0.0029,
        0.003,
        0.0031,
        0.003,
        0.003,
        0.0037,
        0.0043,
        0.0037,
        0.0031,
        0.0025,
        0.0019,
        0.0013,
        0.0006,
        0.0008,
        0.0009,
        0.001,
        0.0011,
        0.0012,
        0.0013
      ],
      "range": 1
    }
  }
]