    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica Q / prf-ie2024-leica-q-gc-occ62@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica Q / prf-ie2024-leica-q-gc-occ62@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0014,
        0.0012,
        0.0011,
        0.0019,
        0.0027,
        0.0017,
        0.0002,
        0.0017,
        0.0034,
        0.0062,
        0.0089,
        0.0094,
        0.0084,
        0.0072,
        0.0068,
        0.0074,
        0.0078,
        0.0071,
        0.0065,
        0.0078,
        0.0092,
        0.0096,
        0.0094,
        0.0095,
        0.0103,
        0.0118,
        0.0133,
        0.0167,
        0.0203,
        0.0241,
        0.0279,
        0.0237,
        0.0194,
        0.0147,
        0.0131,
        0.0136,
        0.0141,
        0.0237,
        0.0334,
        0.1345,
        0.2636,
        0.4132,
        0.5628,
        0.6103,
        0.6322,
        0.5869,
        0.5416,
        0.5,
        0.4613,
        0.4243,
        0.3892,
        0.3618,
        0.3345,
        0.2914,
        0.2443,
        0.194,
        0.1425,
        0.089,
        0.0427,
        0.0252,
        0.0103,
        0.0059,
        0.0034,
        0.0022,
        0.001,
        0.0008,
        0.0005,
        0.0003,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica Q / prf-ie2024-leica-q-gc-occ62@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica Q / prf-ie2024-leica-q-gc-occ62@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0106,
        0.0097,
        0.0087,
        0.0128,
        0.0168,
        0.0102,
        0.0009,
        0.0013,
        0.0021,
        0.0046,
        0.0071,
        0.0104,
        0.0143,
        0.0173,
        0.0212,
        0.027,
        0.0351,
        0.0525,
        0.0699,
        0.1282,
        0.1866,
        0.2369,
        0.2819,
        0.3526,
        0.4447,
        0.559,
        0.6732,
        0.7747,
        0.8613,
        0.9255,
        0.9896,
        0.9948,
        1,
        0.9257,
        0.8775,
        0.8469,
        0.8162,
        0.7365,
        0.6568,
        0.573,
        0.4897,
        0.4129,
        0.3362,
        0.2705,
        0.2076,
        0.1473,
        0.087,
        0.0499,
        0.0307,
        0.0217,
        0.0139,
        0.0114,
        0.0089,
        0.0068,
        0.0048,
        0.0036,
        0.0025,
        0.0016,
        0.0008,
        0.0005,
        0.0003,
        0.0002,
        0.0003,
        0.0003,
        0.0004,
        0.0003,
        0.0002,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001,
        0.0001
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica Q / prf-ie2024-leica-q-gc-occ62@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica Q / prf-ie2024-leica-q-gc-occ62@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Image Engineering GmbH & Co. KG; Image Engineering spectral sensitivities workbook (April 2024); src-ie-202404-private; Image Engineering GmbH & Co. KG, Spectral sensitivities workbook (April 2024).; https://image-engineering.de/ Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:380-755,green:380-755,blue:380-755. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=177; documented-gap samples omitted=0; partial channels=red,green,blue. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        380,
        385,
        390,
        395,
        400,
        405,
        410,
        415,
        420,
        425,
        430,
        435,
        440,
        445,
        450,
        455,
        460,
        465,
        470,
        475,
        480,
        485,
        490,
        495,
        500,
        505,
        510,
        515,
        520,
        525,
        530,
        535,
        540,
        545,
        550,
        555,
        560,
        565,
        570,
        575,
        580,
        585,
        590,
        595,
        600,
        605,
        610,
        615,
        620,
        625,
        630,
        635,
        640,
        645,
        650,
        655,
        660,
        665,
        670,
        675,
        680,
        685,
        690,
        695,
        700,
        705,
        710,
        715,
        720,
        725,
        730,
        735,
        740,
        745,
        750,
        755
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0044,
        0.0033,
        0.0022,
        0.0064,
        0.0106,
        0.0073,
        0.002,
        0.0617,
        0.1394,
        0.2892,
        0.439,
        0.5542,
        0.6463,
        0.7006,
        0.7339,
        0.7501,
        0.7626,
        0.7607,
        0.7587,
        0.7602,
        0.7616,
        0.7281,
        0.6715,
        0.5892,
        0.504,
        0.424,
        0.3441,
        0.2905,
        0.2357,
        0.1789,
        0.1221,
        0.1037,
        0.0853,
        0.0651,
        0.0508,
        0.0405,
        0.0302,
        0.0241,
        0.018,
        0.0147,
        0.0123,
        0.0108,
        0.0092,
        0.0081,
        0.007,
        0.0059,
        0.0048,
        0.0042,
        0.004,
        0.0041,
        0.0042,
        0.0045,
        0.0047,
        0.0054,
        0.0061,
        0.0061,
        0.0053,
        0.0035,
        0.002,
        0.0011,
        0.0004,
        0.0003,
        0.0002,
        0.0001,
        0.0001,
        0.0001,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0
      ],
      "range": 1
    }
  }
]