    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 500D / prf-jiang-intake-canon-500d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 500D / prf-jiang-intake-canon-500d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00189063043478 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.006331485931768791,
        0.008389252239864555,
        0.01785874441303387,
        0.011078253758957683,
        0.008741192002583992,
        0.009872074468424892,
        0.014865066862905174,
        0.026341545520132754,
        0.04642631282410974,
        0.06492813179267959,
        0.08438666651335533,
        0.11478690062877937,
        0.13182416015609452,
        0.1524898158246367,
        0.1713224337492755,
        0.23075515936190427,
        0.2559898190323974,
        0.32814636713666673,
        0.5399311922876998,
        0.5066823927715526,
        0.4456361845408517,
        0.4194281399307724,
        0.34528506449647056,
        0.2938886999874248,
        0.2216357265232439,
        0.18413068493901896,
        0.13844187601503424,
        0.10552430502342318,
        0.0467950040345681,
        0.009946839295227801,
        0.0020042445337665475,
        0.00048126133336485934,
        0.00047457714817923625
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 500D / prf-jiang-intake-canon-500d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 500D / prf-jiang-intake-canon-500d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00189063043478 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008376042037967551,
        0.017054577058436018,
        0.07171329247586306,
        0.08898102424627646,
        0.12423705834576375,
        0.1429623071311489,
        0.1938966758270188,
        0.3764589143160084,
        0.6451661894851423,
        0.7849773353442149,
        0.8758031022548265,
        0.9803245195098818,
        0.9546673129329017,
        0.9979699988523345,
        0.8947730630284184,
        0.8667527300741434,
        0.7026473308223128,
        0.6381886830818724,
        0.5931518999437373,
        0.4102747696383535,
        0.2590493930787599,
        0.1516364696747984,
        0.08972088311778872,
        0.0638067167520191,
        0.04393293156182088,
        0.03421162447804125,
        0.025938918674261152,
        0.02295293759673845,
        0.012638952486788734,
        0.0034942719053149204,
        0.0008210413234272311,
        0.00022675944593500126,
        0.00022361000918590403
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 500D / prf-jiang-intake-canon-500d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 500D / prf-jiang-intake-canon-500d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00189063043478 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04110136945348342,
        0.12164093233108854,
        0.6055299397869738,
        0.8302017265173611,
        0.9156758050674274,
        0.9665911608350868,
        1,
        0.9551356401632961,
        0.9058596549728446,
        0.7809726243059631,
        0.6192537570858582,
        0.4811446224133504,
        0.31232968069082084,
        0.234473051230356,
        0.1794521930547411,
        0.1553113491850283,
        0.11313308683061123,
        0.10150703023238972,
        0.1036600040997565,
        0.0788652726638812,
        0.05679322517218779,
        0.04089797212460668,
        0.02944827578532803,
        0.024876223912662185,
        0.020162751957594083,
        0.018910257147330127,
        0.016431107287619377,
        0.014323580387109972,
        0.007057247579090047,
        0.0017298884276772948,
        0.00037162207223263464,
        0.0001109176185330081,
        0.000109377096053383
      ],
      "range": 1
    }
  }
]