[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D50 / prf-jiang-intake-nikon-d50@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D50 / prf-jiang-intake-nikon-d50@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.041004775,
        0.026891682926829266,
        0.019332380952380955,
        0.014989139534883721,
        0.012676636363636364,
        0.01054323111111111,
        0.010617397826086956,
        0.01414987234042553,
        0.019312979166666668,
        0.016365102040816325,
        0.019822,
        0.032391313725490194,
        0.05814303846153846,
        0.091871,
        0.05406,
        0.029368745454545455,
        0.027491857142857144,
        0.07278945614035089,
        0.3305737931034483,
        0.5629947457627119,
        0.5147360000000001,
        0.4384750819672131,
        0.3179316129032258,
        0.27049349206349205,
        0.19228234375,
        0.1471932307692308,
        0.09656439393939394,
        0.07091479104477612,
        0.049373397058823536,
        0.034175014492753626,
        0.021771642857142857,
        0.015573788732394366,
        0.0098845
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D50 / prf-jiang-intake-nikon-d50@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D50 / prf-jiang-intake-nikon-d50@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.049768324999999995,
        0.053007756097560976,
        0.0646852380952381,
        0.08434888372093022,
        0.1086765,
        0.1343491111111111,
        0.19393391304347826,
        0.28818468085106386,
        0.42434229166666665,
        0.43083591836734697,
        0.5407696,
        0.7475909803921569,
        0.8411405769230769,
        1,
        0.8989879629629629,
        0.862550909090909,
        0.6963821428571428,
        0.583790350877193,
        0.4023339655172414,
        0.26463169491525423,
        0.12472666666666667,
        0.04777037704918033,
        0.016954870967741936,
        0.009365015873015872,
        0.0052282843749999995,
        0.0031514615384615383,
        0.0021687439393939393,
        0.0025712910447761197,
        0.0031787529411764705,
        0.003691411594202898,
        0.003454842857142857,
        0.003021970422535212,
        0.0018530125000000002
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D50 / prf-jiang-intake-nikon-d50@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nikon D50 / prf-jiang-intake-nikon-d50@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.35959175,
        0.4644480487804878,
        0.5658759523809523,
        0.7097316279069767,
        0.8222588636363636,
        0.9150037777777777,
        0.9798432608695652,
        0.8936025531914894,
        0.845979375,
        0.6196997959183674,
        0.4164846,
        0.2555327450980392,
        0.10345192307692308,
        0.045772,
        0.022653574074074076,
        0.012323945454545454,
        0.005873725000000001,
        0.003772019298245614,
        0.0027694327586206898,
        0.0018091864406779663,
        0.0011847266666666666,
        0.0006118198360655738,
        0.00043258258064516133,
        0.00036071126984126977,
        0.00033595375000000004,
        0.00042914507692307693,
        0.0004678775757575758,
        0.00043075552238805974,
        0.0003696282352941177,
        0.00027977855072463766,
        0.000203414,
        0.00014399577464788732,
        0.00007051355555555555
      ],
      "range": 1
    }
  }
]
