    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nokia N900 / prf-jiang-intake-nokia-n900@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nokia N900 / prf-jiang-intake-nokia-n900@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00174569811321 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.003351667711463219,
        0.002597325566865837,
        0.0029476541486658,
        0.0025024972061955847,
        0.0026666851716839824,
        0.002603606589663959,
        0.0038480930034971708,
        0.009688619199022013,
        0.01854797597688478,
        0.029148037157406357,
        0.05217282376083526,
        0.08390597933040621,
        0.13069490333276243,
        0.17432610622338468,
        0.17281635518919622,
        0.17066368490246056,
        0.1576426224496413,
        0.14976163089897634,
        0.4204621603510516,
        0.9293839046617955,
        0.9547278845391727,
        0.6578888990868277,
        0.8405547486177655,
        0.8542905110856517,
        0.6970527955513284,
        0.35507064432076857,
        0.10638272437087853,
        0.052972862928607214,
        0.020208500490185483,
        0.008230418523256042,
        0.006291220312080215,
        0.0032451604201634873,
        0.001031663039901621
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nokia N900 / prf-jiang-intake-nokia-n900@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nokia N900 / prf-jiang-intake-nokia-n900@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00174569811321 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020418765266639285,
        0.021963398553593846,
        0.029851613155584104,
        0.031246245393301803,
        0.04396782288635038,
        0.053009038090640295,
        0.08773741709374878,
        0.2015775891369367,
        0.3442868092633824,
        0.4212921890833245,
        0.5906061261105467,
        0.7561444845550247,
        0.9494878972651826,
        1,
        0.9328327917204077,
        0.8859701181635424,
        0.7841827966784733,
        0.6765302287516634,
        0.5385257858522372,
        0.43373449612900133,
        0.27833182017970504,
        0.286747042174462,
        0.14792122675618213,
        0.12141410897382451,
        0.10025537845053067,
        0.052287655493163374,
        0.016684303749542287,
        0.009247465790306589,
        0.00450106461165993,
        0.0023729554020681014,
        0.0021281702884564904,
        0.0011518859161323185,
        0.00041196508217865297
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Nokia N900 / prf-jiang-intake-nokia-n900@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Nokia N900 / prf-jiang-intake-nokia-n900@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: Documented source-quantity evidence (https://www.gujinwei.org/research/camspec/supp.pdf): Jiang supplementary materials section 1 defines camera signal divided by spectrometer-measured illuminant radiance and exposure time. This documents an energy-response source convention for the original 28-camera dataset. The derived relative photon model divides sensitivity by wavelength; exact optics and calibration accuracy remain unverified. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Jun Jiang; Jiang et al. WACV 2013 camera spectral sensitivity database; src-jiang-wacv2013-original; Jiang et al. WACV 2013 camera spectral sensitivity database; https://www.gujinwei.org/research/camspec/db.html Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00174569811321 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.3659281035861741,
        0.4372141418178194,
        0.6146947289756567,
        0.6581894036013056,
        0.700475169541986,
        0.7194192852630846,
        0.754762204617844,
        0.7178253636742866,
        0.6141764481240497,
        0.5311716264725124,
        0.4068171894252178,
        0.2953703432909014,
        0.2413735693631286,
        0.23386870149802208,
        0.2104856742780696,
        0.18635941132428452,
        0.1603533676932436,
        0.1483245141885647,
        0.1355153927975378,
        0.12954848301768995,
        0.0991198489728569,
        0.09168956182685484,
        0.06974471982600824,
        0.07023796656856901,
        0.06512885111108709,
        0.03786362661354555,
        0.012524293976272964,
        0.0070878713154789805,
        0.0031420094680184173,
        0.0013052375478891194,
        0.0011853628635042784,
        0.0007036532765256287,
        0.00029668169012054787
      ],
      "range": 1
    }
  }
]