[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad / prf-sobotka-ref-hasselblad-334c38bc5b6f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad / prf-sobotka-ref-hasselblad-334c38bc5b6f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011502243600193116,
        0.010942955588697754,
        0.009814236650934954,
        0.00888091594270785,
        0.009347578025254318,
        0.010581617101862225,
        0.014842147030393774,
        0.023967037160028418,
        0.02847157567446919,
        0.02914893201928431,
        0.037154612338454816,
        0.044464117655450386,
        0.05004395753030135,
        0.058435235440177175,
        0.06496719448111302,
        0.06937468975467025,
        0.05942317768570339,
        0.06370319254522284,
        0.10749900332006461,
        0.3031039262065645,
        0.46937840190860963,
        0.5171642540648813,
        0.3500228322391169,
        0.3233853702735628,
        0.23392655008297866,
        0.16061444745631595,
        0.10760807885646402,
        0.07642087788665186,
        0.047978999893232524,
        0.026945697346755133,
        0.017900053082510047,
        0.011725050634589895,
        0.007116546082506177
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad / prf-sobotka-ref-hasselblad-334c38bc5b6f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad / prf-sobotka-ref-hasselblad-334c38bc5b6f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010795847069157604,
        0.014395802544962737,
        0.018709348341343156,
        0.025697520890356724,
        0.036082728682556214,
        0.05489334838548262,
        0.09524714034219578,
        0.18554308007287124,
        0.2677040446036164,
        0.3259959653032182,
        0.47450443438650175,
        0.6858626078269682,
        0.8672691403085444,
        1,
        0.9579034993149631,
        0.9386754466490761,
        0.7832826803303408,
        0.6715505593823143,
        0.47600228747203566,
        0.3109680249414781,
        0.1339134275457275,
        0.059443825819994765,
        0.02213607016973119,
        0.01812501087616947,
        0.01201133332936258,
        0.0085565822866661,
        0.006527125969324695,
        0.006095334129205098,
        0.005275680438647604,
        0.004190989338190272,
        0.0038902260441408855,
        0.0029877055452179786,
        0.0018728641184218135
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad / prf-sobotka-ref-hasselblad-334c38bc5b6f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad / prf-sobotka-ref-hasselblad-334c38bc5b6f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.26010420922875566,
        0.38299667656254466,
        0.44231962984516404,
        0.5201895230897383,
        0.5840588678389051,
        0.7109244513766894,
        0.7595700553369972,
        0.8274338977320125,
        0.8575964023466455,
        0.8067275187351078,
        0.7025550886509052,
        0.5607812139200049,
        0.3848919023138231,
        0.25189097093186796,
        0.14909558112597948,
        0.09058619185253411,
        0.05355979822911747,
        0.04229956996691365,
        0.031947714909070814,
        0.026033202303138943,
        0.01890870065655381,
        0.01574756037431083,
        0.010346704387483622,
        0.010878356206894627,
        0.008874546643922987,
        0.007381464535491754,
        0.0058704773409117735,
        0.004987475144557286,
        0.003601062340957142,
        0.002395548358009043,
        0.001931432421319272,
        0.0013960730062333275,
        0.0008916165341726349
      ],
      "range": 1
    }
  }
]
