    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD200 / prf-sobotka-ref-nikond200-64864059135f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD200 / prf-sobotka-ref-nikond200-64864059135f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0024105292704233714,
        0.005003677030257203,
        0.03384897794568203,
        0.06435891934620662,
        0.047989075285830615,
        0.038085298898698536,
        0.031849997730028265,
        0.03534032500501501,
        0.039010048405902525,
        0.034521270867421947,
        0.03509883084712279,
        0.04270134516121227,
        0.06972319290117317,
        0.08229001355341863,
        0.03629321549108173,
        0.01959866415311152,
        0.021437818233751908,
        0.07988415369077563,
        0.4127935448164565,
        0.712804909014882,
        0.6169543968101179,
        0.5481585363912125,
        0.4350664635938998,
        0.3525819638745308,
        0.26778331922577264,
        0.22014271140393465,
        0.13933138542734422,
        0.05503249476330092,
        0.010954956391658503,
        0.001874225457481958,
        0.0008046718850350877,
        0.0004667237271930468,
        0.00027791574808581974
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD200 / prf-sobotka-ref-nikond200-64864059135f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD200 / prf-sobotka-ref-nikond200-64864059135f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0025483536345511184,
        0.0038536393214581095,
        0.02901942249590728,
        0.08252134692899746,
        0.09935862347152845,
        0.12674966004097893,
        0.17995813734266242,
        0.3004700395766466,
        0.38058411652901103,
        0.41355488231698656,
        0.5816723011801388,
        0.7906579666054998,
        0.9256226158505001,
        1,
        0.8638868802594047,
        0.8874877014555816,
        0.6385632198548571,
        0.5271074463252334,
        0.3623217204368696,
        0.246979571423281,
        0.11603165106150333,
        0.0557024554436263,
        0.028534172787447014,
        0.01842284109150321,
        0.012813765912514227,
        0.00999846069900839,
        0.007304412973466584,
        0.0041184050487848385,
        0.0012659642464183276,
        0.00034821157595483555,
        0.00021880089628612294,
        0.00015476026308640684,
        0.00010391111051549797
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD200 / prf-sobotka-ref-nikond200-64864059135f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD200 / prf-sobotka-ref-nikond200-64864059135f@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.007603687723699726,
        0.025082493859166558,
        0.2834777889212867,
        0.7893313722265043,
        0.8636830710842676,
        0.9944341083798016,
        0.9601804536613435,
        0.9508185133438154,
        0.8475699920885998,
        0.6453786197372222,
        0.4338446409774367,
        0.2501319911330506,
        0.10194362215026459,
        0.041642244630333246,
        0.01849359940897061,
        0.008707530308004576,
        0.002283796066179601,
        0.0013110265012019927,
        0.0005072260918619367,
        0.0003853339347140468,
        0.00048202884709580774,
        0.0003373107044719353,
        0.000325058688407306,
        0.000367521222078778,
        0.00021555768326573678,
        0.0004675389985507154,
        0.0006617738966877138,
        0.000399124936646658,
        0.00012189386430980144,
        0.000051750808828995904,
        0.00004333197725215565,
        0.00003431091480259573,
        0.000028493908585775664
      ],
      "range": 1
    }
  }
]