[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD40 / prf-sobotka-ref-nikond40-e48e7ccf213d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD40 / prf-sobotka-ref-nikond40-e48e7ccf213d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.03307333689208351,
        0.02733092300387033,
        0.020191319924379073,
        0.01651776229932582,
        0.012603269731090124,
        0.010254115458335215,
        0.009924983750291856,
        0.015763114640394538,
        0.018755778884054723,
        0.016717130203074554,
        0.021251067295154493,
        0.038069917903382024,
        0.07605619294885156,
        0.09647923290686074,
        0.05060374949664381,
        0.030573753521917737,
        0.033347862820855216,
        0.10284393645939134,
        0.41168961776918533,
        0.606431591106893,
        0.5078132116299098,
        0.43499148200721444,
        0.321070008577416,
        0.2533672338486959,
        0.17702773365959873,
        0.12663233103827082,
        0.09220381860458964,
        0.062288139946196315,
        0.03964040066471486,
        0.027296400761787062,
        0.016755144924634157,
        0.011356676340984336,
        0.007248258619082421
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD40 / prf-sobotka-ref-nikond40-e48e7ccf213d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD40 / prf-sobotka-ref-nikond40-e48e7ccf213d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04622579394334634,
        0.06381970360341148,
        0.08107605109239913,
        0.10697889344017951,
        0.12168260582057645,
        0.1542805923516867,
        0.21075077019498814,
        0.3293885671753371,
        0.4257351984418202,
        0.462130870674201,
        0.585281691639307,
        0.8198217083390139,
        0.899550446053084,
        1,
        0.8869692939436677,
        0.843557178031826,
        0.660501117010316,
        0.534616066797627,
        0.35343767342074406,
        0.23878810137425668,
        0.10463198133384335,
        0.04257028469044125,
        0.01662458891441619,
        0.008979985977788135,
        0.004942465425017218,
        0.00285165274348963,
        0.0022903434963747393,
        0.0024806625351112034,
        0.0026932222728480028,
        0.0029853796763872026,
        0.002688193945650151,
        0.0021680419992760936,
        0.0013482575927773251
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD40 / prf-sobotka-ref-nikond40-e48e7ccf213d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NikonD40 / prf-sobotka-ref-nikond40-e48e7ccf213d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00188679245283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.3187252961130184,
        0.5241112968411926,
        0.6631931877070206,
        0.8331456177399614,
        0.8660133343005579,
        0.9752154063565276,
        0.9548201214058062,
        0.8991994332190669,
        0.791683015700801,
        0.5981701861449764,
        0.38529487746944396,
        0.22635354775227118,
        0.08731341474722942,
        0.035779070455327217,
        0.01793692685106097,
        0.010812349687510813,
        0.0055996726455373015,
        0.0035002190934405853,
        0.003101129520091122,
        0.002632870041543583,
        0.0015508197479193765,
        0.0009483573984127595,
        0.0006379186597628362,
        0.00047854401846419384,
        0.0006032241234631792,
        0.00048286201384284514,
        0.0004208740719253384,
        0.0004287820194078556,
        0.00035588375141270607,
        0.0002678562515518697,
        0.00021139507244764962,
        0.00016958538520571605,
        0.0001264488572853494
      ],
      "range": 1
    }
  }
]
