[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NokiaN900 / prf-sobotka-ref-nokian900-219e8e3477a7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NokiaN900 / prf-sobotka-ref-nokian900-219e8e3477a7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00174570598702 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0033516026384695185,
        0.0025972745809207704,
        0.0029476465582564753,
        0.0025025372883236835,
        0.0026666090503741674,
        0.002603601081257311,
        0.0038480641279544977,
        0.009688585452356908,
        0.018547756997047,
        0.029147938943978234,
        0.0521725476097346,
        0.08390542017418882,
        0.1306931541101756,
        0.17431997509250788,
        0.17281454348788258,
        0.17066628319057933,
        0.15764670634621555,
        0.14976288946980246,
        0.4204649759873159,
        0.9293808845263251,
        0.954723578345939,
        0.6578861014261098,
        0.8405479321347384,
        0.8542911979639778,
        0.6970485800673325,
        0.355071516809129,
        0.10638364698248892,
        0.05297237701484667,
        0.020208627414620668,
        0.008230373604083208,
        0.006291181206190944,
        0.0032451118331588208,
        0.0010316350059589488
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NokiaN900 / prf-sobotka-ref-nokian900-219e8e3477a7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NokiaN900 / prf-sobotka-ref-nokian900-219e8e3477a7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00174570598702 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020418628840037707,
        0.021963275968481355,
        0.029851003964654368,
        0.031245773019115,
        0.04396699457650714,
        0.053008470822879086,
        0.08773664265775365,
        0.2015815151454914,
        0.3442871335269617,
        0.42128896900966706,
        0.5905993842727922,
        0.7561460636264493,
        0.9494799571599465,
        1,
        0.9328251859567148,
        0.8859617823531164,
        0.7841751391962515,
        0.6765238127916743,
        0.5385264893184093,
        0.4337361768743475,
        0.2783348798173486,
        0.2867465397102429,
        0.1479202040954441,
        0.12141248619955589,
        0.10025593273931337,
        0.05228784642419442,
        0.01668387853556519,
        0.009247145594064452,
        0.004501061626068299,
        0.002372981848360583,
        0.0021281567564964735,
        0.0011519108912122385,
        0.0004119657541070283
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / NokiaN900 / prf-sobotka-ref-nokian900-219e8e3477a7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / NokiaN900 / prf-sobotka-ref-nokian900-219e8e3477a7@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Sobotka (depositor); Sobotka Jiang 2013 camera spectral sensitivity mirror; src-sobotka-jiang2013-mirror; Sobotka, camera-spectral-sensitivity, pinned revision ae75f609f5831dc1b9287f9f89a04c1d93ed4efa, 2013.; https://github.com/sobotka/camera-spectral-sensitivity Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-720,green:400-720,blue:400-720. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00174570598702 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700,
        710,
        720
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.36592845147273156,
        0.4372098289501988,
        0.6146853147947945,
        0.6581897712572107,
        0.7004778258693082,
        0.7194199101587821,
        0.7547565401476135,
        0.7178193729316832,
        0.6141776754050522,
        0.5311729074534511,
        0.4068116443981614,
        0.29536875038887145,
        0.24137539097381616,
        0.2338718829979056,
        0.21048308969641238,
        0.1863612342244053,
        0.16034872830379018,
        0.1483254924765391,
        0.13551102561223632,
        0.12954346135297612,
        0.09912201116746236,
        0.0916887931255401,
        0.0697441325262628,
        0.07023783017669709,
        0.06512857379069326,
        0.03786373437577634,
        0.012523998254510053,
        0.007087809392690932,
        0.0031419658543035854,
        0.0013052367827228603,
        0.0011853795108251947,
        0.0007036537105276929,
        0.0002966841677847155
      ],
      "range": 1
    }
  }
]
