[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 10D (Huynh-2007) / prf-solomatov-gt-canon-10d-huynh-2007-ae0354e36c86@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 10D (Huynh-2007) / prf-solomatov-gt-canon-10d-huynh-2007-ae0354e36c86@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.9896 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.9896; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.008403395311236864,
        0.012605092966855296,
        0.02521018593371059,
        0.016806790622473727,
        0.012605092966855296,
        0.021008488278092156,
        0.04621867421180275,
        0.27311034761519803,
        0.4453819725141471,
        0.5378132578819725,
        0.5420169765561843,
        0.5084074373484236,
        0.41596604688763134,
        0.3361358124494745,
        0.27731406628940986,
        0.19328011317704122,
        0.1428556992724333,
        0.08403395311236862,
        0.02941188358932902,
        0.004201697655618432,
        0.004201697655618432
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 10D (Huynh-2007) / prf-solomatov-gt-canon-10d-huynh-2007-ae0354e36c86@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 10D (Huynh-2007) / prf-solomatov-gt-canon-10d-huynh-2007-ae0354e36c86@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.9896 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.9896; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016806790622473727,
        0.02941188358932902,
        0.04201697655618431,
        0.05462206952303961,
        0.07142886014551333,
        0.11344987873888439,
        0.20588116410670979,
        0.2941188358932902,
        0.3823565076798706,
        0.4579830234438157,
        0.5924413904607922,
        0.7773140662894098,
        0.899161277283751,
        1,
        0.9831952303961196,
        0.9117724333063865,
        0.8067299919159256,
        0.6008387227162489,
        0.42016976556184316,
        0.2857113985448666,
        0.17227162489894907,
        0.08403395311236862,
        0.04621867421180275,
        0.02521018593371059,
        0.012605092966855296,
        0.012605092966855296,
        0.008403395311236864,
        0.008403395311236864,
        0,
        0,
        0
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 10D (Huynh-2007) / prf-solomatov-gt-canon-10d-huynh-2007-ae0354e36c86@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Canon 10D (Huynh-2007) / prf-solomatov-gt-canon-10d-huynh-2007-ae0354e36c86@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.9896 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.9896; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.07563055780113176,
        0.16386418755052545,
        0.26050929668552947,
        0.3697453516572352,
        0.5168047696038804,
        0.6932801131770412,
        0.7310933710590137,
        0.7395008084074373,
        0.7058811641067098,
        0.596645109135004,
        0.5042037186742118,
        0.3655517380759903,
        0.22688965238480194,
        0.13445836701697655,
        0.04621867421180275,
        0.012605092966855296,
        0.004201697655618432,
        0.004201697655618432,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0,
        0
      ],
      "range": 1
    }
  }
]
