[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1.03 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1.03; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.029126213592233007,
        0.029126213592233007,
        0.029126213592233007,
        0.029126213592233007,
        0.029126213592233007,
        0.038834951456310676,
        0.04854368932038835,
        0.0679611650485437,
        0.07766990291262135,
        0.07766990291262135,
        0.0970873786407767,
        0.10679611650485436,
        0.11650485436893203,
        0.11650485436893203,
        0.1262135922330097,
        0.1359223300970874,
        0.1262135922330097,
        0.1262135922330097,
        0.18446601941747573,
        0.36893203883495146,
        0.5922330097087378,
        0.6019417475728155,
        0.5339805825242718,
        0.44660194174757284,
        0.36893203883495146,
        0.2718446601941748,
        0.21359223300970873,
        0.1553398058252427,
        0.1262135922330097,
        0.08737864077669902,
        0.0679611650485437
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1.03 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1.03; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.038834951456310676,
        0.038834951456310676,
        0.04854368932038835,
        0.058252427184466014,
        0.08737864077669902,
        0.11650485436893203,
        0.17475728155339804,
        0.2912621359223301,
        0.3883495145631068,
        0.42718446601941745,
        0.5825242718446602,
        0.7281553398058253,
        0.9029126213592233,
        1,
        0.9902912621359223,
        0.970873786407767,
        0.8932038834951457,
        0.7961165048543689,
        0.6504854368932039,
        0.49514563106796117,
        0.2912621359223301,
        0.1941747572815534,
        0.11650485436893203,
        0.07766990291262135,
        0.058252427184466014,
        0.038834951456310676,
        0.029126213592233007,
        0.029126213592233007,
        0.029126213592233007,
        0.029126213592233007,
        0.029126213592233007
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=1.03 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1.03; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.2621359223300971,
        0.3786407766990291,
        0.42718446601941745,
        0.49514563106796117,
        0.6019417475728155,
        0.6796116504854368,
        0.7475728155339806,
        0.8155339805825242,
        0.8349514563106796,
        0.8155339805825242,
        0.7184466019417476,
        0.6019417475728155,
        0.44660194174757284,
        0.2912621359223301,
        0.1941747572815534,
        0.1359223300970874,
        0.08737864077669902,
        0.0679611650485437,
        0.058252427184466014,
        0.058252427184466014,
        0.04854368932038835,
        0.038834951456310676,
        0.038834951456310676,
        0.029126213592233007,
        0.029126213592233007,
        0.019417475728155338,
        0.019417475728155338,
        0.019417475728155338,
        0.019417475728155338,
        0.009708737864077669,
        0.009708737864077669
      ],
      "range": 1
    }
  }
]
