[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00194339622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1.03; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.03859223300970874,
        0.03765095903386218,
        0.036754507628294034,
        0.03589975163693836,
        0.03508384819064431,
        0.04573894282632147,
        0.05593077247783875,
        0.07663705845899607,
        0.08576051779935275,
        0.08401030315038636,
        0.1029126213592233,
        0.11098419950504473,
        0.11874533233756535,
        0.11650485436893204,
        0.12387630348795398,
        0.13097969991173875,
        0.11945214979195562,
        0.11735649804121955,
        0.16856377636424508,
        0.3314135264110581,
        0.5231391585760518,
        0.522998567563266,
        0.4564672721578453,
        0.3757127446447835,
        0.30552184466019416,
        0.22165795369678867,
        0.1715210355987055,
        0.12288074192146066,
        0.09837235865219875,
        0.06711692697340649,
        0.05145631067961165
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00194339622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1.03; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05145631067961165,
        0.05020127871181625,
        0.06125751271382339,
        0.07179950327387671,
        0.10525154457193292,
        0.1372168284789644,
        0.2013507809202195,
        0.3284445362528403,
        0.42880258899676377,
        0.462056667327125,
        0.6174757281553398,
        0.7567104511707595,
        0.9202763256161315,
        1,
        0.9719525350593312,
        0.9355692850838482,
        0.8453536754507629,
        0.7402486799523079,
        0.5944091061265484,
        0.444791838077999,
        0.25728155339805825,
        0.16870921534298902,
        0.09959285937989351,
        0.06534134689474495,
        0.04824029126213592,
        0.03166542195668409,
        0.023389232127096204,
        0.02304013911027387,
        0.022701313535122784,
        0.022372308991135497,
        0.02205270457697642
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 (Mauer-2009) / prf-solomatov-gt-leica-m8-mauer-2009-6db864a7bc9d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=Per-record measurements reported in 10 nm steps over the 400-700 nm range.; source=Jun Jiang; Solomatov / Akkaynak ICCP 2023 ground-truth camera measurements (measured subset); src-solomatov-gt-measured-2026-09-13; COLOR-Lab-Eilat, Spectral-sensitivity-estimation, pinned revision e9958089605676c27437ea98665490d40f104d5d, data/ground-truths/ (measured subset), 2023.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00194339622642 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=1.03; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.34733009708737866,
        0.48946246744020844,
        0.5390661118816459,
        0.6102957778279521,
        0.7250661959399823,
        0.8004314994606256,
        0.8613338961587168,
        0.9196447015079529,
        0.921925566343042,
        0.8821081830790568,
        0.7615533980582524,
        0.6255473063011612,
        0.4551904406273338,
        0.2912621359223301,
        0.19057892844300614,
        0.13097969991173875,
        0.08269764216366157,
        0.06319196048373361,
        0.05323066622028791,
        0.05232845153858812,
        0.04288025889967638,
        0.03374184306859781,
        0.03319761979329784,
        0.02450300508552936,
        0.02412014563106796,
        0.015832710978342046,
        0.015592821418064135,
        0.015360092740182582,
        0.01513420902341519,
        0.0074574363303785,
        0.007350901525658807
      ],
      "range": 1
    }
  }
]
