[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Casio EX F1 / prf-solomatov-pred-casio-ex-f1-dc80d9b75544@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Casio EX F1 / prf-solomatov-pred-casio-ex-f1-dc80d9b75544@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2775763 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2775763; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011612229502302611,
        0.020338481707552123,
        0.02648556595069536,
        0.0040210817710301635,
        0.019195060961616682,
        0.03394825494827909,
        0.05092584273225056,
        0.06010786943986213,
        0.07861328939106112,
        0.07465914777306276,
        0.06058578127887719,
        0.055109150168800435,
        0.05726988939617684,
        0.04359960486540097,
        0.025561028445151835,
        0.026216871901527616,
        0.06921096649822048,
        0.27397832595938487,
        0.5752336204495845,
        0.7105646267350635,
        0.6758473616083217,
        0.612554061712041,
        0.5281411633486001,
        0.45676107794505516,
        0.38630953002832014,
        0.31373256650513753,
        0.24039283973451625,
        0.15910796418858525,
        0.08941523465800214,
        0.03687196277203782,
        0.028371889098600996
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Casio EX F1 / prf-solomatov-pred-casio-ex-f1-dc80d9b75544@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Casio EX F1 / prf-solomatov-pred-casio-ex-f1-dc80d9b75544@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2775763 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2775763; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.017095527968346003,
        0.02624491356070385,
        0.0530822660291963,
        0.0921504861906438,
        0.12975210779882865,
        0.15648573022985032,
        0.20488034461155366,
        0.2981958834381754,
        0.4151318754519028,
        0.5429929356360756,
        0.6902841488988793,
        0.8563147502146257,
        0.9655759515491776,
        1,
        0.9741274741395428,
        0.9077105646267352,
        0.8065183518909936,
        0.6611540322426662,
        0.4959674871377708,
        0.35362590394064625,
        0.23852180463533812,
        0.15282202767311187,
        0.10610792419958044,
        0.07280849265589318,
        0.046100791025746796,
        0.026700031666968688,
        0.019869676914059307,
        0.008387850475707039,
        0.004672944700249986,
        0.0052584846040530115,
        0.0008556775560449505
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Casio EX F1 / prf-solomatov-pred-casio-ex-f1-dc80d9b75544@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Casio EX F1 / prf-solomatov-pred-casio-ex-f1-dc80d9b75544@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2775763 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2775763; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04909659794442105,
        0.11961352608273834,
        0.27773215868934054,
        0.4558879486469125,
        0.5804933274202445,
        0.6711474286529505,
        0.7327215616030619,
        0.7319391461014504,
        0.6748177708255352,
        0.5532822146559343,
        0.4092782921308483,
        0.2789186612834021,
        0.17795603226932558,
        0.1130836818561239,
        0.09086654732410512,
        0.07486107423436367,
        0.06996732069704799,
        0.06736239369139224,
        0.06265613094489696,
        0.04665739113894089,
        0.02583446785622548,
        0.011760783251307838,
        0.004014311740591686,
        0.0036070723617254064,
        0.0030875467394010222,
        0.0033549562048344906,
        0.004251090240773438,
        0.0028249288573988485,
        0.0013135779243400824,
        0.0009856340040558219,
        0.002099184620589006
      ],
      "range": 1
    }
  }
]
