[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / CASIO EX FH100 / prf-solomatov-pred-casio-ex-fh100-b3ec8329b0a3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / CASIO EX FH100 / prf-solomatov-pred-casio-ex-fh100-b3ec8329b0a3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27173075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27173075; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015790341726138832,
        0.026106165754151856,
        0.02380587033304107,
        0.0009475512064792078,
        0.0006217846526386874,
        0.0008273297740502316,
        0.0008699504196709426,
        0.005630396265420825,
        0.030790711025528023,
        0.025258620895868427,
        0.02441330471431739,
        0.03503243560031392,
        0.050937061778985264,
        0.03814242959252863,
        0.010053402126921594,
        0.004484030975515284,
        0.06279553565431957,
        0.34345798552427353,
        0.7050889897444437,
        0.8348956825828507,
        0.7766250599168477,
        0.6754881808554976,
        0.5761850287462865,
        0.5114587141867455,
        0.4437407617650928,
        0.3558880619878317,
        0.2803720594743142,
        0.18795314847509895,
        0.10388848888099708,
        0.04390989242108226,
        0.023628485182483026
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / CASIO EX FH100 / prf-solomatov-pred-casio-ex-fh100-b3ec8329b0a3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / CASIO EX FH100 / prf-solomatov-pred-casio-ex-fh100-b3ec8329b0a3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27173075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27173075; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018215194268591244,
        0.031201132002910963,
        0.05672616919505797,
        0.0846856934667865,
        0.11922878437571013,
        0.1508078125129379,
        0.19876039057044517,
        0.29355411560892536,
        0.418186605674919,
        0.5408618641798913,
        0.6813613843850944,
        0.8468014753574999,
        0.9632013307290396,
        1,
        0.9751241992303042,
        0.9022253462296776,
        0.7983944400845322,
        0.6836242125707156,
        0.5727394856857385,
        0.4335322005330644,
        0.2898840856252006,
        0.17659109246929172,
        0.12401897834529214,
        0.1107426781841952,
        0.10569683409036333,
        0.09359213854155261,
        0.09409215924219101,
        0.06587134507228201,
        0.039969881951159365,
        0.0246408476037401,
        0.010661778249241206
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / CASIO EX FH100 / prf-solomatov-pred-casio-ex-fh100-b3ec8329b0a3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / CASIO EX FH100 / prf-solomatov-pred-casio-ex-fh100-b3ec8329b0a3@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27173075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27173075; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04268473111710765,
        0.10734316966335242,
        0.25868408341713256,
        0.4467070804463609,
        0.5590575229340072,
        0.6220492896000912,
        0.6629370801795528,
        0.6424702393821825,
        0.5665759948036797,
        0.46321157984512235,
        0.34687971089028385,
        0.25355698609745125,
        0.18932650794950515,
        0.16709422838600343,
        0.17865596735003306,
        0.19795762165305175,
        0.21312059823924967,
        0.1787109224848494,
        0.11217605294947294,
        0.08047336931870978,
        0.08244223739860136,
        0.0787654544066139,
        0.056856653139182804,
        0.01409552470598193,
        0.00037497051769076555,
        0.00009928308445032444,
        0.000008606849979253358,
        0.000035492368824654545,
        0.000019264012262138164,
        0.0002691628385819418,
        0.0012575015893490154
      ],
      "range": 1
    }
  }
]
