[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.25822714 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25822714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013631770851042224,
        0.023126065292749628,
        0.023657095067544022,
        0.00003831986056926471,
        0.000022438814913103246,
        0.007498112320804079,
        0.04687145200926594,
        0.08461619100145708,
        0.13139974365204213,
        0.12926746197165798,
        0.10067542861683709,
        0.06369530716252365,
        0.029273527949076148,
        0.00007461544514647065,
        0.000022897314356655152,
        0.00008658560056855371,
        0.00010890470691810317,
        0.16460794942003384,
        0.5864491625473603,
        0.8109594134838033,
        0.7875758527937845,
        0.7115456183265632,
        0.6192909854479277,
        0.5528830160919568,
        0.49357522993129216,
        0.42502178508424787,
        0.35292219865038194,
        0.2585860649659056,
        0.1476590841690769,
        0.057245845653559106,
        0.04213766221474629
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.25822714 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25822714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018253793927315305,
        0.0317311960315248,
        0.06478317499856907,
        0.10986862961035,
        0.15871017662976863,
        0.1953367798597777,
        0.2407290999698947,
        0.32449915992563755,
        0.4283212446220796,
        0.5410288399584954,
        0.6784333358608239,
        0.8405728770415068,
        0.9554570832484919,
        1,
        0.9903653039723089,
        0.939883894465934,
        0.8605535808513388,
        0.7308129191997401,
        0.5698517591915395,
        0.4306654366384571,
        0.3297390041960732,
        0.24939781310361103,
        0.19092434668176242,
        0.13171527981140943,
        0.08031515587401077,
        0.037669437070015174,
        0.014222743976485198,
        0.000002528948854872497,
        0.000011850630030600192,
        0.002665938599637513,
        0.000741699342679472
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm GFX 100S / prf-solomatov-pred-fujifilm-gfx-100s-1fc0b5cb2431@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.25822714 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.25822714; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04850288393388859,
        0.1218190039977982,
        0.28705489283581886,
        0.47662987709192767,
        0.6013762147541888,
        0.6916356661813317,
        0.7596299908677299,
        0.7726302510262864,
        0.7320974859575179,
        0.6279611430463893,
        0.490259234563803,
        0.3585165137947932,
        0.24479123302066544,
        0.16106030915263206,
        0.1193459448143212,
        0.08602741756734013,
        0.06640729165803408,
        0.06769387601938355,
        0.08167716995200426,
        0.06298099804691326,
        0.024223594003325907,
        0.0012416807931188022,
        0.0010912501296339338,
        0.000059420256910253505,
        0.00013427706708133002,
        0.005966107977650993,
        0.011778860657326723,
        0.011675136083681984,
        0.0064153736900002065,
        0.0015801589252005036,
        0.002548078215171341
      ],
      "range": 1
    }
  }
]
