[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00049920009434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26457605; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013530509261892752,
        0.026926348296343265,
        0.03187565980331463,
        0.005600017110304368,
        0.024278404502736974,
        0.041711953477606485,
        0.05809371289259371,
        0.06700479929177101,
        0.08302630976361365,
        0.07670004028663044,
        0.060633842707985094,
        0.046513188796589416,
        0.037476821227481014,
        0.01827079397398215,
        0.00008643933477447887,
        0.00019493800948897126,
        0.037881979018887006,
        0.21395346412138447,
        0.48023366256031624,
        0.6263722808557505,
        0.6095621844834405,
        0.551980244571968,
        0.47102303184965694,
        0.40854600922902634,
        0.34797444345397094,
        0.28494305512535995,
        0.22631444222490346,
        0.15588852655792135,
        0.09165129831401639,
        0.03505380701352767,
        0.022949217274741446
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00049920009434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26457605; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022603984610474,
        0.03521479312225599,
        0.0712665654391332,
        0.12036608861259272,
        0.16455714674991795,
        0.19593996920314172,
        0.24624163580878194,
        0.34523413927155167,
        0.4645370048926701,
        0.5871344063108369,
        0.7274898865562471,
        0.8867437206821711,
        0.9846047972857824,
        1,
        0.9598615232571895,
        0.8805357455995939,
        0.7771674999359487,
        0.6405053895275564,
        0.4948673840985254,
        0.3640713267860868,
        0.2597943719773577,
        0.1812779120953171,
        0.13375084062512155,
        0.09187751049092995,
        0.06034111877993114,
        0.03526038534826972,
        0.02210404715335528,
        0.008747813657290935,
        0.00464986537785972,
        0.0042216361401296665,
        0.0006408089734501667
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T1 IR / prf-solomatov-pred-fujifilm-x-t1-ir-0e78ee3702ab@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00049920009434 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26457605; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06428113268377843,
        0.15557033684459418,
        0.3566571078883512,
        0.5822128260189909,
        0.738218874549062,
        0.8461390851095134,
        0.9206550482817947,
        0.9301346782860208,
        0.8815863301244891,
        0.746708143161137,
        0.5716243711401693,
        0.4032780315053119,
        0.2591021684284377,
        0.16094730418720818,
        0.11790610900946095,
        0.08704899651554043,
        0.07316552961399404,
        0.062087647820107235,
        0.04976080445001312,
        0.02685155063502471,
        0.00001265948612254712,
        0.000005377939097686875,
        0.00002866525254391915,
        0.000040526741489033806,
        0.000002093055994675255,
        0.000025399927399091717,
        0.000007861107804410686,
        0.0000020666755446640237,
        0.000010887039267493165,
        0.000009234204869546439,
        0.0010855820693412832
      ],
      "range": 1
    }
  }
]
