[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T30 II / prf-solomatov-pred-fujifilm-x-t30-ii-caa0f1472df5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T30 II / prf-solomatov-pred-fujifilm-x-t30-ii-caa0f1472df5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000507266037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.268851; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01096235079095856,
        0.029988225430152577,
        0.033883835638469244,
        0.0012066323371128106,
        0.016299630718062487,
        0.03858945950648417,
        0.06787794047228034,
        0.0856112105756277,
        0.11671054521525553,
        0.11147640021227143,
        0.09290920442921916,
        0.07552421754713468,
        0.06353630106238428,
        0.03385035577327219,
        0.00033975548104092353,
        0.00010075795596141289,
        0.03664899616463075,
        0.2400950953919757,
        0.5301914930703188,
        0.6573854354081453,
        0.6235666162050106,
        0.5530667270084575,
        0.46656697479992815,
        0.3945788707062795,
        0.3318508927807596,
        0.26407751333810003,
        0.2025775818373205,
        0.14001383083133714,
        0.07756400461922162,
        0.030694298857095504,
        0.021929578847975802
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T30 II / prf-solomatov-pred-fujifilm-x-t30-ii-caa0f1472df5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T30 II / prf-solomatov-pred-fujifilm-x-t30-ii-caa0f1472df5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000507266037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.268851; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023541371512473448,
        0.038984412165556204,
        0.07429561151857703,
        0.11724558757496263,
        0.16193351090719055,
        0.20091191072791661,
        0.26450421778800054,
        0.3704629407556839,
        0.4949524388043935,
        0.6120680341944961,
        0.746470711286177,
        0.8989783706274799,
        0.9875342697685277,
        1,
        0.9580996750644063,
        0.8773352614036636,
        0.7715042280455928,
        0.6292068449575572,
        0.47391078239850576,
        0.3390609942789179,
        0.2326108482641562,
        0.15551055155116386,
        0.10912686976993252,
        0.07215018739653573,
        0.04412732278985385,
        0.02398683079532472,
        0.014425599433639203,
        0.0036942427467869486,
        0.0007190819236852601,
        0.0033717713097804994,
        0.00036848579377743483
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T30 II / prf-solomatov-pred-fujifilm-x-t30-ii-caa0f1472df5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Fujifilm X T30 II / prf-solomatov-pred-fujifilm-x-t30-ii-caa0f1472df5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000507266037736 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.268851; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06258671020379317,
        0.14497059346772095,
        0.33223057168681325,
        0.5519999050221731,
        0.6962434557363811,
        0.7841708587863001,
        0.8450171041887917,
        0.850089499071581,
        0.8024749977682806,
        0.6939962230805486,
        0.5466628147189335,
        0.4044988896466524,
        0.27585320350448617,
        0.18215221814313504,
        0.1318300761250518,
        0.09169448160031865,
        0.07196511888953892,
        0.06444898044680981,
        0.06499969538312401,
        0.046752009824104566,
        0.017679194609653674,
        0.00013428043639992924,
        0.00008113100139050518,
        0.00003934364251916725,
        0.0026062359820123414,
        0.006572221216041027,
        0.010030283705641617,
        0.008523275240344245,
        0.004088865880663836,
        0.0015441236924563406,
        0.0021392046311366304
      ],
      "range": 1
    }
  }
]
