[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-rear-telephoto-camera-9382960f6b20@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-rear-telephoto-camera-9382960f6b20@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000507818490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2691438; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01689773542990773,
        0.030105316898416026,
        0.029945471793994777,
        0.00006138917490929938,
        0.0001066029874600999,
        0.013956865206546753,
        0.045395569895285,
        0.07337054447821637,
        0.1102282422228068,
        0.11263865112938413,
        0.10160931702680871,
        0.08926732074663665,
        0.07284642111820465,
        0.03706332451276976,
        0.00001462572375945636,
        0.00007636554970377781,
        0.034350919603997145,
        0.276495601392658,
        0.5817387755362465,
        0.6900988358299447,
        0.6418974615057081,
        0.5660957097722604,
        0.47576981572316457,
        0.4015253243333177,
        0.33712693067098337,
        0.2719520902952251,
        0.20978454246166525,
        0.13908263022198655,
        0.07911621708849889,
        0.03278233541358544,
        0.022509119607118152
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-rear-telephoto-camera-9382960f6b20@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-rear-telephoto-camera-9382960f6b20@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000507818490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2691438; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024246324186178538,
        0.03918855083343878,
        0.07256315981058666,
        0.11202466773316666,
        0.15098290140133944,
        0.19153292329230692,
        0.2579561489143496,
        0.37343856941270015,
        0.5119951498356393,
        0.6348482772224441,
        0.7656276941917295,
        0.9080188943095644,
        0.9902146476230294,
        1,
        0.9575706342084018,
        0.8773718976452535,
        0.7754777265642275,
        0.6349710745509904,
        0.48829186517931406,
        0.3561547137658288,
        0.24888969979369147,
        0.1680888631915325,
        0.12054657356809546,
        0.08288136658686159,
        0.05500108962430121,
        0.03214870666507301,
        0.022960463722592184,
        0.009894298856363452,
        0.005191535643333984,
        0.005868918270520783,
        0.0007556897226368527
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-rear-telephoto-camera-9382960f6b20@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-rear-telephoto-camera-9382960f6b20@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000507818490566 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2691438; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06000863855121315,
        0.1408334965881599,
        0.3252317852814316,
        0.5458310364285769,
        0.6801428016614842,
        0.7569921283715249,
        0.8022405107054943,
        0.7870688322858589,
        0.7227706736138823,
        0.6189520703984188,
        0.48880512350646754,
        0.37336671486161876,
        0.2727604272683056,
        0.20202204174868604,
        0.16105399432213202,
        0.12803284016675373,
        0.10437368213041293,
        0.09329175991395612,
        0.08456747515896579,
        0.05823510753579767,
        0.027093407563788082,
        0.004695008825740896,
        0.00021406365835517264,
        0.000016644809554040607,
        0.0027796613627176256,
        0.00554398693475098,
        0.009291892548507414,
        0.0063011837327419705,
        0.0036736003917520934,
        0.001979571278371949,
        0.00178022634846396
      ],
      "range": 1
    }
  }
]
