[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 XL Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-xl-rear-telephoto-camera-48f6edb17325@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 XL Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-xl-rear-telephoto-camera-48f6edb17325@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510235660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2704249; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015466360179850303,
        0.027133980365082015,
        0.029328558061600025,
        0.0000738996008237063,
        0.005986225422894253,
        0.02252436189616168,
        0.04922842477828812,
        0.07088210292670785,
        0.10302746259990604,
        0.10469497997335274,
        0.09595985894790013,
        0.0903836873299875,
        0.08137587075575681,
        0.05463588966844399,
        0.02010348837452961,
        0.010759056984363897,
        0.0632424051530969,
        0.28549222859441215,
        0.5684888006576521,
        0.675362472106122,
        0.6304708947536513,
        0.5568122040173221,
        0.4677133544166021,
        0.3909606773026154,
        0.32488693227537474,
        0.2585785554510698,
        0.1954407485360552,
        0.1289961149751273,
        0.06856648582852175,
        0.02886130005468956,
        0.02142468749311599
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 XL Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-xl-rear-telephoto-camera-48f6edb17325@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 XL Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-xl-rear-telephoto-camera-48f6edb17325@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510235660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2704249; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024132505734494124,
        0.038525335499800493,
        0.07004229877817146,
        0.10711933047791877,
        0.14568167640157126,
        0.18503273116574034,
        0.2516166828733146,
        0.3704529348900209,
        0.5130833397121838,
        0.6414566174662654,
        0.7746429163882467,
        0.9145858087859251,
        0.9937380993904265,
        1,
        0.9537800478952716,
        0.8723949593264659,
        0.766689146281595,
        0.6263131737070848,
        0.47929962096303086,
        0.34418771774545304,
        0.23481322972354496,
        0.1541300333381246,
        0.1080251628861386,
        0.07390832904833648,
        0.04917999247434315,
        0.028923145021039112,
        0.020134264409061218,
        0.009560283591963455,
        0.00543801777042242,
        0.005781437071915292,
        0.002325518143590222
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 XL Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-xl-rear-telephoto-camera-48f6edb17325@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Google Pixel 4 XL Rear Telephoto Camera / prf-solomatov-pred-google-pixel-4-xl-rear-telephoto-camera-48f6edb17325@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000510235660377 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2704249; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0562136865909907,
        0.13730171594730384,
        0.3207949046112248,
        0.5369206188156593,
        0.6737827766599894,
        0.7545784274220967,
        0.8044457589262063,
        0.795139633017081,
        0.7371508811996725,
        0.6375981362844101,
        0.5066161777262376,
        0.3874329476229706,
        0.2796359067356024,
        0.20193329090627377,
        0.15776690675112195,
        0.12336384105834255,
        0.0989526793892553,
        0.08631277576283088,
        0.07723448396744632,
        0.05341568993894234,
        0.023364860447392232,
        0.0035633483079260285,
        0.00005757868188292786,
        0.00012893126388456515,
        0.0036283246522417125,
        0.007079927607940745,
        0.009380445645935619,
        0.0076764727623250565,
        0.004290514847299237,
        0.0017661992213959844,
        0.0012680648659625226
      ],
      "range": 1
    }
  }
]
