[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27866584 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27866584; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010572955048957562,
        0.01993130912637157,
        0.022771807983353827,
        0.0018273927295860879,
        0.009214019917188272,
        0.024112083490391217,
        0.039990330354090046,
        0.056942989495949704,
        0.07717820024155096,
        0.07762514415114533,
        0.06479067186706486,
        0.05679608595011143,
        0.05462669195477996,
        0.04684486623835918,
        0.032737855490289014,
        0.03721656016395838,
        0.08371583686037729,
        0.2686463471805514,
        0.5054910928443902,
        0.619033750243661,
        0.5979909127003152,
        0.541972995326589,
        0.46350937739623915,
        0.388692564542536,
        0.3190492957443223,
        0.2514216668968109,
        0.18891669678637324,
        0.12510934242962826,
        0.07075902091192807,
        0.029587978921277184,
        0.020138464047118228
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27866584 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27866584; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014944207011523193,
        0.02654833330127582,
        0.05399936353878179,
        0.08934634040541173,
        0.12484623160126122,
        0.14935169305286936,
        0.19487637953758524,
        0.28364725292486515,
        0.38529387024975864,
        0.4958833131466706,
        0.6431320035494842,
        0.825513453676274,
        0.9543311803125923,
        1,
        0.9812770736449073,
        0.914038261740298,
        0.8128048992298447,
        0.6651837196837618,
        0.504687370364448,
        0.35316111942533035,
        0.2317743358855897,
        0.14015302342045224,
        0.09259973881262232,
        0.06460933281237485,
        0.04235926979783385,
        0.024780376381977786,
        0.02047045127597986,
        0.009884337814782033,
        0.0022001708928514525,
        0.005693494042900988,
        0.0003390336433055447
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27866584 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27866584; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04381069455804127,
        0.10620663444073375,
        0.25814541890028575,
        0.44898797068201823,
        0.5879381556060118,
        0.6851533363400408,
        0.7677843470157663,
        0.802919080429808,
        0.7877439157953483,
        0.6945093449559515,
        0.5414754101184415,
        0.3745524568063312,
        0.22103284708308704,
        0.11139427423181829,
        0.06722966115976037,
        0.03891314055572796,
        0.04133784750940409,
        0.05004833387544021,
        0.05618522169778686,
        0.05089972635325521,
        0.043670210887706944,
        0.03289430451898948,
        0.020081618184704664,
        0.009275115672591948,
        0.0013520823004355325,
        0.00006614720340318713,
        0.00011147677806508326,
        0.000029353303583962783,
        0.00007236480079510284,
        0.00046061662958043223,
        0.001488892395278876
      ],
      "range": 1
    }
  }
]
