    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000525784603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27866584; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01400916543986877,
        0.025764863017016908,
        0.028735852931375067,
        0.0022523677829782013,
        0.011098705809340418,
        0.02839867611090521,
        0.046075815407973314,
        0.06421230730394328,
        0.08521759610004585,
        0.08396189061246331,
        0.06867811217908876,
        0.05902338343835109,
        0.05567720526160265,
        0.04684486623835918,
        0.03213159890713552,
        0.0358632307034508,
        0.07923105988571422,
        0.249793971939811,
        0.46191427449573585,
        0.5560811654731193,
        0.5282253062186117,
        0.47089456970998717,
        0.39622575809678506,
        0.32699533207546677,
        0.2642126980382669,
        0.20500535916201504,
        0.15170583226784518,
        0.098967091772691,
        0.05515041335782629,
        0.02272699830185059,
        0.015247694207103802
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000525784603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27866584; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01980107429026823,
        0.034318577194332164,
        0.06814205398941511,
        0.1101245591043447,
        0.1503829607924283,
        0.17590310515115726,
        0.2245314807715656,
        0.3198575405322947,
        0.4254286484007752,
        0.5363635836076233,
        0.6817199237624534,
        0.8578865302910299,
        0.9726837030109113,
        1,
        0.9631052759848165,
        0.8808005067679235,
        0.7692617796282458,
        0.6185041604077084,
        0.4611798384364783,
        0.3172464293142798,
        0.20473399669893758,
        0.12177229903744212,
        0.0791578412430481,
        0.054353883159616936,
        0.03507877030133116,
        0.020205537665304963,
        0.01643839269131716,
        0.007818953793782803,
        0.0017148390782518676,
        0.004373263540199309,
        0.00025669690135991243
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 100 20 Coated6 / prf-solomatov-pred-hasselblad-100-20-coated6-a9619778da8d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000525784603774 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27866584; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.058049170289404685,
        0.13729150305753388,
        0.3257549333741701,
        0.5534037778173713,
        0.7081982328890598,
        0.8069583739116036,
        0.8846210954746873,
        0.9054193885697834,
        0.8698005736906971,
        0.751203985360519,
        0.573963934725548,
        0.3892407884457951,
        0.2252834787577618,
        0.11139427423181829,
        0.06598466743457963,
        0.0374981172627924,
        0.03912331996425745,
        0.046536170094707556,
        0.05134166810315006,
        0.045723482995297056,
        0.0385753529508078,
        0.028580297368958073,
        0.017166544577247537,
        0.007802875089640845,
        0.0011196931550481754,
        0.00005393541200567566,
        0.00008951923087044564,
        0.00002321977746194071,
        0.00005640197709030074,
        0.00035380697634439,
        0.0011273042421397204
      ],
      "range": 1
    }
  }
]