[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 39 Coated / prf-solomatov-pred-hasselblad-39-coated-3f1515cf7f97@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 39 Coated / prf-solomatov-pred-hasselblad-39-coated-3f1515cf7f97@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00054347645283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28804252; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010288968309262118,
        0.020946239244766244,
        0.0329436579776651,
        0.02666374051868421,
        0.05953009022607305,
        0.06939652597895,
        0.07300457087105539,
        0.06653852059389069,
        0.0661481817279384,
        0.0680806921229858,
        0.07673026086565277,
        0.09377365345567866,
        0.1169883853499236,
        0.1347929465413648,
        0.13744177872175362,
        0.1519813274285149,
        0.18186127644329336,
        0.2636232615812805,
        0.38523024847763493,
        0.4521157942649037,
        0.42452044695808566,
        0.3726095799226072,
        0.3092239796917438,
        0.25077192252010744,
        0.19604839721232825,
        0.14560002407336892,
        0.10537276800787479,
        0.06710601465076815,
        0.0393334807366798,
        0.014806713258861919,
        0.0086299735787024
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 39 Coated / prf-solomatov-pred-hasselblad-39-coated-3f1515cf7f97@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 39 Coated / prf-solomatov-pred-hasselblad-39-coated-3f1515cf7f97@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00054347645283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28804252; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02085971699594907,
        0.030814270161461904,
        0.05371617051207446,
        0.07806426230824984,
        0.09368825659047585,
        0.1127219398024986,
        0.16738343684995444,
        0.28531776961853456,
        0.42161523062636724,
        0.5465618019711471,
        0.700605257168282,
        0.8756608252986876,
        0.980203107086145,
        1,
        0.9548165216615833,
        0.8648832685598576,
        0.7487663409902121,
        0.6050744564659071,
        0.45370969284625773,
        0.3063002210311619,
        0.18606581660235438,
        0.10076484040403844,
        0.061363595756850464,
        0.0419073602424866,
        0.02691615291945439,
        0.020205442382390144,
        0.0233137320447963,
        0.011221526143628782,
        0.000013128217192500933,
        0.00623769221817406,
        0.0016738309627739286
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 39 Coated / prf-solomatov-pred-hasselblad-39-coated-3f1515cf7f97@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 39 Coated / prf-solomatov-pred-hasselblad-39-coated-3f1515cf7f97@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00054347645283 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28804252; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.061684084610147134,
        0.14734638872743935,
        0.3383399313010157,
        0.5508519181513993,
        0.6947595058661351,
        0.7974568538623318,
        0.86789604731002,
        0.8802606118486153,
        0.8377909738233553,
        0.7202133935515024,
        0.5597938943181028,
        0.3999728819993142,
        0.2589549245662118,
        0.16504254302455068,
        0.12045061019566244,
        0.09007490358778217,
        0.07606343804727163,
        0.06049898161843264,
        0.04548642966873852,
        0.027550062365203954,
        0.007204359967410367,
        0.0005998899262010822,
        0.00010564222125619598,
        0.00007326371941572851,
        0.00009608830516584843,
        0.000021579654634109095,
        0.0005976460876384331,
        0.000036850082711980034,
        0.005689615516405253,
        0.00020285664819529953,
        0.0014297683451139685
      ],
      "range": 1
    }
  }
]
