[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2842977 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2842977; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009924623730687938,
        0.0200295658389076,
        0.027637618946618283,
        0.007041998581064848,
        0.03362520343991527,
        0.0516035725930952,
        0.06479341901112812,
        0.07358371172190278,
        0.08364924162242608,
        0.07647075583094763,
        0.06869235312139352,
        0.06756223142149936,
        0.0770691602499774,
        0.08445791154835232,
        0.08981044517771336,
        0.10857655549095192,
        0.1610839693743565,
        0.293697697870929,
        0.4569125603196931,
        0.5413229864328837,
        0.517052793603325,
        0.4625679701242747,
        0.3884211163157493,
        0.3154608355959264,
        0.2471989256332359,
        0.18389909591248893,
        0.13163737518805113,
        0.08242587963251198,
        0.045903512409702925,
        0.01886252227858333,
        0.010287028350915255
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2842977 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2842977; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015140273030699862,
        0.02498813743480865,
        0.05196211225064431,
        0.08360207275683201,
        0.11368602348875845,
        0.1376627739162153,
        0.18268162915141417,
        0.27745570927939267,
        0.3905704126343618,
        0.5064871084078415,
        0.6565524800235809,
        0.833397280386018,
        0.9578947349908213,
        1,
        0.9794099635698778,
        0.9073232038106535,
        0.8013438026406827,
        0.6562658790415822,
        0.49900498667418,
        0.34398994434355257,
        0.20976145779582459,
        0.11440818198669916,
        0.06807394854056154,
        0.047939111009339855,
        0.033118688614083056,
        0.0252875795337071,
        0.029502563685882794,
        0.016285831717949176,
        0.006230980060689904,
        0.00799131860722053,
        0.0018852755403930457
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2842977 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2842977; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04324089853699133,
        0.1090888740921928,
        0.2573281282261517,
        0.4356904962650067,
        0.571846940724459,
        0.6740256076640789,
        0.7580449648379146,
        0.7980114858474058,
        0.7897746974386356,
        0.7019821827612395,
        0.5574464724828938,
        0.3963557214849083,
        0.24427563079124454,
        0.13375839832682432,
        0.08359671569625783,
        0.05437951133618035,
        0.04940261915590594,
        0.04416645298220844,
        0.034280010003598343,
        0.02017852975947396,
        0.012708113009707783,
        0.0038701062301946163,
        0.000014611860736122733,
        0.00004011620037728058,
        0.000001765699476288412,
        0.00009896303065413474,
        7.380018550976669e-7,
        0.000010865247942561619,
        0.000009632148272743677,
        0.00002462841697277185,
        0.00009118224312050362
      ],
      "range": 1
    }
  }
]
