    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000536410754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2842977; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013150126443161518,
        0.025891877791758597,
        0.03487604295644688,
        0.00867967266968458,
        0.04050308596171612,
        0.0607775410540899,
        0.07465328712151718,
        0.08297737704810314,
        0.09236270429142879,
        0.08271326651102498,
        0.07281389430867713,
        0.07021173069293071,
        0.07855125948555387,
        0.0844579115483523,
        0.08814728878553348,
        0.10462831710946274,
        0.15245447101501597,
        0.2730873331080567,
        0.41752354649902984,
        0.4862731912024208,
        0.456729967682937,
        0.40190331830469767,
        0.33203740588281794,
        0.26538768708863647,
        0.20471161029002344,
        0.14994849359018328,
        0.1057088012873744,
        0.06520256150034529,
        0.03577773761344493,
        0.014488604069056759,
        0.00778875003712155
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000536410754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2842977; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.020060861765677316,
        0.03230173863524045,
        0.06557123688771782,
        0.10304441525842084,
        0.13693998283873174,
        0.16213615594576467,
        0.2104810075005424,
        0.31287558705974067,
        0.43125483061710773,
        0.5478329948084816,
        0.6959456288249958,
        0.8660795266756657,
        0.9763157875867986,
        1,
        0.9612727420222873,
        0.8743296327629932,
        0.7584146703563603,
        0.6102121331439272,
        0.45598731540916443,
        0.3090079161052251,
        0.18528928771964506,
        0.09940383025073861,
        0.05819224633306066,
        0.04032972830944464,
        0.027426414008537528,
        0.020619103312099634,
        0.02369145265684527,
        0.012882822105243379,
        0.004856499164949484,
        0.006138259220038958,
        0.0014274229091547344
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Hasselblad 50 15 Coated5 / prf-solomatov-pred-hasselblad-50-15-coated5-40b2d4df1f23@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000536410754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2842977; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05729419056151351,
        0.1410173250460053,
        0.32472359038062,
        0.5370138674894268,
        0.688815633145371,
        0.7938523823599151,
        0.873399633400206,
        0.8998852925513298,
        0.8720428950884935,
        0.7592868507417487,
        0.5908932608318674,
        0.4118990831117674,
        0.24897323907569152,
        0.1337583983268243,
        0.08204862836854934,
        0.05240207456031924,
        0.046756050272553834,
        0.04106705277293066,
        0.03132483672742607,
        0.01812647588562915,
        0.011225499825241873,
        0.0033625513147592565,
        0.000012490784177653303,
        0.000033748549523743976,
        0.000001462219878801341,
        0.00008069293268721754,
        5.926378533360052e-7,
        0.000008594897626205459,
        0.000007507409683167866,
        0.000018917479703723303,
        0.00006903798407695273
      ],
      "range": 1
    }
  }
]