    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27468508 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27468508; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014325166841970445,
        0.025054910153838712,
        0.027200954999084766,
        0.008953745139706896,
        0.011957386982940608,
        0.01967640725153328,
        0.04125091541193282,
        0.059743630778926894,
        0.087808431386226,
        0.07801859860753994,
        0.05119389811780094,
        0.02087806516466056,
        0.00000793799575863385,
        0.0000912671121416569,
        0.000008527358311561734,
        0.0025594940577041893,
        0.0031612346764520296,
        0.19324154773895982,
        0.5579520736983603,
        0.725098975160937,
        0.7024711353088416,
        0.6438497496842566,
        0.556981143642749,
        0.4888348868456925,
        0.4264135132494273,
        0.3522617245902107,
        0.27752115258680954,
        0.19317950214114285,
        0.11108365259591092,
        0.04435995213136439,
        0.03377726231071596
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27468508 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27468508; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01629481659506224,
        0.027730662691981666,
        0.053265499531317824,
        0.0882508434750078,
        0.1260099019575435,
        0.14359128278827518,
        0.17190176474091712,
        0.2400370999400477,
        0.3336606414880633,
        0.45309454011845124,
        0.6058434990353316,
        0.7933164771817967,
        0.9348924229885365,
        1,
        0.9968844321650087,
        0.9491877025137295,
        0.8614183558859476,
        0.7192925804342922,
        0.5534717065812238,
        0.4100257138101567,
        0.3103983660124532,
        0.2322729359745349,
        0.18774371363744982,
        0.13774022236664618,
        0.08910559321241619,
        0.04776880855705741,
        0.030789367955478323,
        0.008548701298228501,
        0.0017824537466687306,
        0.008266269868024867,
        0.0000031694014833277434
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27468508 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27468508; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04791869292645964,
        0.11679150902553571,
        0.27360353900546763,
        0.45814093725076005,
        0.58565889344991,
        0.6763623637658077,
        0.744002986984222,
        0.7480228995328031,
        0.6893631426941718,
        0.564101333789225,
        0.4046715970157534,
        0.2552291518709352,
        0.1416503109670172,
        0.07222443243003951,
        0.05774740659376184,
        0.053370594427625984,
        0.06726832050725143,
        0.08362685734514592,
        0.08737819687913154,
        0.07366531156333644,
        0.04532585097086452,
        0.018183437556928826,
        0.00004030494848864744,
        0.000003800957081469441,
        0.000011578793431372392,
        0.000010922264507413361,
        0.00253095996331508,
        0.0025744574477798354,
        0.003384606837764905,
        0.0001744776017685416,
        0.0029777066886923745
      ],
      "range": 1
    }
  }
]