[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000518273735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27468508; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01898084606561084,
        0.032388054589108574,
        0.0343250146417022,
        0.011036011451266639,
        0.014403216138542094,
        0.02317443520736142,
        0.04752822862679216,
        0.0673704772613431,
        0.09695514298895787,
        0.08438746379999218,
        0.054265532004868985,
        0.021696812818176658,
        0.000008090649523222962,
        0.0000912671121416569,
        0.000008369444268755035,
        0.0024664215465149465,
        0.0029918828187849565,
        0.17968073737131351,
        0.5098527570002258,
        0.6513600963310111,
        0.6205161695228101,
        0.5594104382502556,
        0.47612904214622087,
        0.4112420476638365,
        0.3531236906596819,
        0.28722879081971026,
        0.22285789525910463,
        0.15281363602209808,
        0.08657990569975409,
        0.03407358641974366,
        0.025574212892399226
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000518273735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27468508; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021590631988457468,
        0.035846954211586055,
        0.06721598750380582,
        0.10877429544593985,
        0.1517846546306774,
        0.16911862195063523,
        0.19806072894062188,
        0.2706801339749474,
        0.3684169583097366,
        0.4900818495158758,
        0.6421941089774515,
        0.8244269272673572,
        0.9528711234306236,
        1,
        0.978423609347138,
        0.9146717860586847,
        0.815270943963486,
        0.6688159081231138,
        0.5057586284276699,
        0.3683281835921746,
        0.2741852233110003,
        0.20181091158443196,
        0.1604905939158845,
        0.11587669500686107,
        0.07379056937903215,
        0.038949951592677584,
        0.024724795479399257,
        0.006762405504568815,
        0.0013892654201976867,
        0.006349453666743738,
        0.000002399689694519577
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad7,1 back camera / prf-solomatov-pred-ipad7-1-back-camera-f1b6249c8611@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000518273735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27468508; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06349226812755901,
        0.1509743897159364,
        0.34526160874499484,
        0.5646853412625646,
        0.7054527580192097,
        0.7966045617686178,
        0.857220832829647,
        0.8435151845795439,
        0.7611718033914813,
        0.6101504222618148,
        0.4289518928366986,
        0.26523813821881503,
        0.1443743554086906,
        0.07222443243003951,
        0.05667801017535884,
        0.05142984553934868,
        0.06366466048007725,
        0.0777583059525041,
        0.07984559369989606,
        0.06617392394672597,
        0.040037835024263654,
        0.015798724434708655,
        0.00003445423015965022,
        0.0000031976305606012756,
        0.000009588688310355261,
        0.00000890584644450628,
        0.0020324375462984733,
        0.0020365111154079293,
        0.00263800238825794,
        0.0001340190274454015,
        0.00225454935000994
      ],
      "range": 1
    }
  }
]
