    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2737615 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2737615; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011874894022716853,
        0.02274807816292649,
        0.02287260261212771,
        0.00013510014008543935,
        0.0000062710494353661855,
        0.00949372537774669,
        0.03309461337697229,
        0.05738074199622665,
        0.08905620403161146,
        0.09283976380900895,
        0.08592822584622016,
        0.07838081687892565,
        0.0676598060720737,
        0.03744009292760304,
        0.00044983907525345966,
        0.00008417002390767147,
        0.04299261218250192,
        0.2777286798910731,
        0.6194305627343508,
        0.7474663530116544,
        0.6969520184540193,
        0.6262463494684242,
        0.5336298201171458,
        0.4559107471284311,
        0.3851930603828515,
        0.31180821992866053,
        0.24219572145827667,
        0.16574185194046642,
        0.09585323721560557,
        0.04239439804355251,
        0.030720514024068397
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2737615 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2737615; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018035359245182393,
        0.028009174043830125,
        0.05368481871994418,
        0.0826323131631,
        0.11420954005585154,
        0.14437604995589226,
        0.19769372245549502,
        0.3020822650372678,
        0.4314217667568303,
        0.5588779649439384,
        0.7016465061741699,
        0.8607244627166348,
        0.9654267674599971,
        1,
        0.9773884567406301,
        0.9171138746682788,
        0.8222999216471272,
        0.6818304253885226,
        0.5264865950836769,
        0.3831007062717,
        0.27247129344338045,
        0.18570802322459512,
        0.1338542965318352,
        0.09102871660185965,
        0.059027715730663365,
        0.03188408706118282,
        0.02132217422829726,
        0.007895501741479355,
        0.003152448901689975,
        0.005505008191436706,
        0.0011766435382623197
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2737615 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2737615; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.042555748342991986,
        0.1066548729459767,
        0.25534256643099923,
        0.43969477081328096,
        0.5663783987156704,
        0.644832089245566,
        0.7016235664985764,
        0.7035606906011255,
        0.658055789437156,
        0.5715223652705,
        0.4530594148556316,
        0.34104576428752764,
        0.24227091829932257,
        0.1724827705868064,
        0.13770628813766728,
        0.11016752903530994,
        0.093225628877691,
        0.08757645980168871,
        0.08699126429392008,
        0.06416729160236191,
        0.030357369462104787,
        0.0063138414276660525,
        0.000054715319721728585,
        0.000010052877048087479,
        0.0021713509752101737,
        0.0068824100540068635,
        0.009061180626202004,
        0.009002791846187283,
        0.005033406450505276,
        0.00218372963327568,
        0.002028692493283387
      ],
      "range": 1
    }
  }
]