    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516531132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2737615; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015734234580099832,
        0.029406052259392784,
        0.02886304615339926,
        0.00016651877731461127,
        0.000007553764092600179,
        0.01118149877823499,
        0.03813075019520721,
        0.06470594310212793,
        0.09833289195157101,
        0.1004185200383158,
        0.09108391939699338,
        0.0814545744035894,
        0.06896095618884435,
        0.03744009292760304,
        0.00044150872200802527,
        0.00008110929576557433,
        0.040689436529867895,
        0.2582389479688925,
        0.5660313762917344,
        0.6714528255867405,
        0.6156409496343838,
        0.5441156806856801,
        0.45616742687433437,
        0.38354396186995,
        0.31898800312954895,
        0.25424362548029245,
        0.1944905035952828,
        0.13110922616186152,
        0.0747091407709867,
        0.03256381298997512,
        0.023259817761080357
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516531132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2737615; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.023896850999866673,
        0.0362069810810487,
        0.06774512838469149,
        0.10184913017777443,
        0.13757058234000302,
        0.17004290328138422,
        0.22777754978567907,
        0.3406459584462808,
        0.4763615341273335,
        0.6045006559597702,
        0.7437452965446202,
        0.8944783632153265,
        0.983992666834228,
        1,
        0.9592886705046927,
        0.883764279225796,
        0.7782481401303168,
        0.6339826762384508,
        0.4810998196454289,
        0.3441413124135611,
        0.2406829758749861,
        0.161352872637763,
        0.11442383413205268,
        0.07657971396664384,
        0.048882327089455606,
        0.025997794065272146,
        0.017122352031814468,
        0.006245695407438892,
        0.002457055761611304,
        0.004228484552842688,
        0.0008908872503986136
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,1 back camera / prf-solomatov-pred-ipad8-1-back-camera-690bbec26731@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516531132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2737615; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.056386366554464384,
        0.13787093332040892,
        0.322218000496261,
        0.5419493686768346,
        0.682228525725694,
        0.7594689051114444,
        0.8083923700961858,
        0.7933769489757373,
        0.7266032675035266,
        0.6181772522313573,
        0.48024297974696956,
        0.3544201079850778,
        0.24692997442046344,
        0.17248277058680642,
        0.13515617169067343,
        0.10616143707038958,
        0.08823139875924327,
        0.08143074332437722,
        0.07949201737203042,
        0.057641804320765794,
        0.026815676358192566,
        0.005485796650267227,
        0.000046772773310509925,
        0.000008457182278549783,
        0.0017981500263459253,
        0.005611811274805596,
        0.007276402624071307,
        0.007121611460416807,
        0.0039230962040702885,
        0.0016773575444001601,
        0.0015360100306288506
      ],
      "range": 1
    }
  }
]