    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27435786 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27435786; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012496095428066104,
        0.02367186054009898,
        0.0242588858216054,
        0.0019145978540581997,
        0.00005035553929455493,
        0.012905083164010683,
        0.03630927322439386,
        0.055732159450434554,
        0.08726567921181481,
        0.09158789181399796,
        0.08622578554884486,
        0.08002732999885623,
        0.07250706795861434,
        0.043996497858672615,
        0.008409401502111146,
        0.003312728273941195,
        0.05229198828129072,
        0.291149974708215,
        0.615585461994783,
        0.7370013018763159,
        0.6955781037219054,
        0.6265771645835114,
        0.5316464780706484,
        0.45175443488296635,
        0.3810990142582392,
        0.3052639862404525,
        0.23440265206908964,
        0.15631700874179438,
        0.09008415140721684,
        0.03757137849085133,
        0.02893162237086993
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27435786 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27435786; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018402523623708103,
        0.02818655897082737,
        0.052805707844491866,
        0.08287576306361334,
        0.11361959886988475,
        0.14401677794104384,
        0.2000902871891478,
        0.30568940142629775,
        0.4338835781850755,
        0.5565840176767671,
        0.6990587402890516,
        0.8616961803099061,
        0.9676157264092963,
        1,
        0.9759527210191827,
        0.9111608101914777,
        0.8157981695877056,
        0.6767080410963987,
        0.5200908040323685,
        0.3796089020376526,
        0.26539416075048844,
        0.1788218496820175,
        0.1287967474305274,
        0.08913141034122368,
        0.05909947686572566,
        0.03444718514716509,
        0.022714958485242596,
        0.009442779587215034,
        0.00398347107679,
        0.005620179061026354,
        0.00023537439751133795
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27435786 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27435786; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.043619030998419364,
        0.10575785946136189,
        0.25141495855085033,
        0.4373442408393184,
        0.5642247318884904,
        0.6436541675897312,
        0.7006941226323896,
        0.7064686610400007,
        0.6645566123019038,
        0.5796115336371264,
        0.4587795297718097,
        0.34461061184833564,
        0.24385889290724166,
        0.17313566303513228,
        0.13703126274567093,
        0.10804518594801694,
        0.09125935010573416,
        0.08460463644088782,
        0.08467997964410423,
        0.06191314876125655,
        0.02973293712088292,
        0.007879941912362198,
        0.004201836608581215,
        0.0005557942097959213,
        0.0021502965870924926,
        0.006654805515686702,
        0.009456888896859016,
        0.007985229947485375,
        0.004227317198056582,
        0.0009781803954878492,
        0.002240096930337625
      ],
      "range": 1
    }
  }
]