    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517656339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27435786; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016557326442187586,
        0.030600209966469408,
        0.030612403536787763,
        0.0023598531689554554,
        0.00006065553596844115,
        0.015199320170945914,
        0.041834597410714665,
        0.0628469032100645,
        0.09635585412971218,
        0.09906445441105902,
        0.09139933268177554,
        0.08316565666547804,
        0.07390143465012615,
        0.043996497858672615,
        0.008253671844664644,
        0.0031922654276160603,
        0.04949063176622157,
        0.2707183975357087,
        0.5625177497538534,
        0.6620520169397413,
        0.6144273249543497,
        0.5444031102119034,
        0.4544719893184574,
        0.3800473817269399,
        0.31559762118260437,
        0.24890755801144585,
        0.18823243272214774,
        0.12365375318380749,
        0.07021264742033077,
        0.028859174782827828,
        0.021905371223658657
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517656339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27435786; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024383343801413233,
        0.03643628354765489,
        0.06663577418471592,
        0.10214919633422109,
        0.13685997136599753,
        0.16961976068611828,
        0.23053880915271374,
        0.3447135803317825,
        0.4790797842460208,
        0.6020194476911971,
        0.7410022647063947,
        0.8954881873808829,
        0.9862237211479367,
        1,
        0.9578795224817903,
        0.8780276898208784,
        0.7720946962169355,
        0.6292197575106865,
        0.47525538989164706,
        0.3410046069151794,
        0.23443150866293141,
        0.15536980382208077,
        0.11010044538416051,
        0.07498356742991834,
        0.04894175427942906,
        0.028087704812303844,
        0.018240799995725115,
        0.007469661464513384,
        0.003104764221615735,
        0.004316949133831837,
        0.000178212043830013
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,5 back camera / prf-solomatov-pred-ipad8-5-back-camera-58580d3aa4fb@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517656339623 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27435786; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05779521607290566,
        0.1367113793037117,
        0.3172617334094064,
        0.5390522038252064,
        0.679634336138409,
        0.7580815751612389,
        0.8073214891199272,
        0.7966561496834051,
        0.7337812594166855,
        0.6269267608728102,
        0.48630630155811816,
        0.35812475348944683,
        0.24854848700161167,
        0.17313566303513228,
        0.13449364676889924,
        0.10411627009536177,
        0.08637045635006983,
        0.07866746897135182,
        0.07737998139892284,
        0.05561689634485758,
        0.02626409445677991,
        0.006846506907462236,
        0.00359189258475491,
        0.00046757290665371155,
        0.0017807143611859705,
        0.005426226035867619,
        0.007594168356568603,
        0.00631667443607052,
        0.003294820757308806,
        0.0007513559559544349,
        0.0016960733901127732
      ],
      "range": 1
    }
  }
]