[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,9 back camera / prf-solomatov-pred-ipad8-9-back-camera-56271bbe9ba1@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,9 back camera / prf-solomatov-pred-ipad8-9-back-camera-56271bbe9ba1@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000514265471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2725607; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016121309821995618,
        0.02763377121804159,
        0.02366209802073447,
        0.0000442752911510618,
        0.00006637451342364871,
        0.00041427691112067477,
        0.029575415917325543,
        0.06112842082593993,
        0.10328519268062736,
        0.11025926050413652,
        0.10116324517804659,
        0.09200109071584608,
        0.0787173804135824,
        0.053196880548076086,
        0.020756357105856504,
        0.01500259349068433,
        0.06710533227749164,
        0.2664786222832617,
        0.5375440507696843,
        0.6504981651948991,
        0.6158112248024019,
        0.5485125824912505,
        0.4602568883827322,
        0.38842859124649576,
        0.32223295237537913,
        0.25383986308088724,
        0.19353802601946965,
        0.1294311765766387,
        0.0745323654186993,
        0.029040333060659063,
        0.020952860828012676
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,9 back camera / prf-solomatov-pred-ipad8-9-back-camera-56271bbe9ba1@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,9 back camera / prf-solomatov-pred-ipad8-9-back-camera-56271bbe9ba1@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000514265471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2725607; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.024434409738821484,
        0.037891139791488115,
        0.06870404682420501,
        0.10438519651790644,
        0.1437289413464097,
        0.17948388002297389,
        0.24152151125937468,
        0.3585264345059534,
        0.4921898589928776,
        0.6172559225395687,
        0.752055545792185,
        0.9020024314497546,
        0.9890030035934692,
        1,
        0.9540041756787606,
        0.8735557927596913,
        0.7669474791696467,
        0.6246042241651255,
        0.47437608551428906,
        0.3383967931310689,
        0.23163597380938145,
        0.15166756808516477,
        0.1063651565770783,
        0.07156663171944906,
        0.044799931320344426,
        0.025260009633422238,
        0.017167587384566026,
        0.005822886654923352,
        0.002623339130351083,
        0.0042535046587654675,
        0.0018050032682103998
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,9 back camera / prf-solomatov-pred-ipad8-9-back-camera-56271bbe9ba1@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPad8,9 back camera / prf-solomatov-pred-ipad8-9-back-camera-56271bbe9ba1@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000514265471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2725607; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05925295723117824,
        0.1418323834188754,
        0.3271360244140986,
        0.5395988745873642,
        0.678864403582228,
        0.7618648763376379,
        0.8160011098285711,
        0.8121772219093201,
        0.7577844448961278,
        0.6547202146164139,
        0.5142487189092192,
        0.3828409511975088,
        0.2627206399839065,
        0.17699107024600394,
        0.1312592137648061,
        0.09758202017852438,
        0.07906390019596685,
        0.07529863436375116,
        0.0778598035922476,
        0.06092146334711959,
        0.03572283709035578,
        0.01631531107821752,
        0.0027920304156693505,
        0.006980102827364374,
        0.010135457704925913,
        0.013715364631127618,
        0.01454542116951408,
        0.011732520712666778,
        0.008114310192835837,
        0.002888118669994653,
        0.0014773060087427971
      ],
      "range": 1
    }
  }
]
