[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,1 back ultra wide camera / prf-solomatov-pred-iphone13-1-back-ultra-wide-camera-a7e67cee3f7d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,1 back ultra wide camera / prf-solomatov-pred-iphone13-1-back-ultra-wide-camera-a7e67cee3f7d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2685545 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2685545; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013786888694845926,
        0.025468280367672114,
        0.02414572945156384,
        0.000008103033090117648,
        0.000025547955442936164,
        0.000021568760158552546,
        0.029579411255443496,
        0.06460247733700236,
        0.10840257005561256,
        0.1115070274376337,
        0.0966451390686062,
        0.07713592957853993,
        0.05634304396314343,
        0.01064564771768859,
        0.000017262478938167115,
        0.00006249786542396423,
        0.000010541137087630259,
        0.25504528875889254,
        0.6298924054521522,
        0.7771505225196376,
        0.733347718991862,
        0.6619552083469092,
        0.5684406330930967,
        0.49223327108650206,
        0.42320590420194043,
        0.3460272682081291,
        0.2713332303126554,
        0.184180857144453,
        0.10766505867524098,
        0.043329722644751816,
        0.03555210953456375
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,1 back ultra wide camera / prf-solomatov-pred-iphone13-1-back-ultra-wide-camera-a7e67cee3f7d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,1 back ultra wide camera / prf-solomatov-pred-iphone13-1-back-ultra-wide-camera-a7e67cee3f7d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2685545 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2685545; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018027111815292613,
        0.029745284476707712,
        0.05820916424785287,
        0.09372740728604437,
        0.1335854249323694,
        0.16606280661839593,
        0.2155091573591208,
        0.31043983623435845,
        0.4303568177036691,
        0.554359171043494,
        0.6917504268221162,
        0.852952529188675,
        0.9607416744087328,
        1,
        0.9828213640061887,
        0.9234534517202282,
        0.8356571571133606,
        0.7020779022507536,
        0.5512689230677572,
        0.4125660675952182,
        0.30334401397109345,
        0.21485899510155296,
        0.16013190618663997,
        0.11188491349055779,
        0.07512422245763896,
        0.04448193569647875,
        0.02985070441940091,
        0.014009590232150272,
        0.005729698813462445,
        0.00766848926381796,
        0.00026174195554347444
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,1 back ultra wide camera / prf-solomatov-pred-iphone13-1-back-ultra-wide-camera-a7e67cee3f7d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,1 back ultra wide camera / prf-solomatov-pred-iphone13-1-back-ultra-wide-camera-a7e67cee3f7d@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2685545 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2685545; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.047349413247590344,
        0.1140081212565792,
        0.2670728846472504,
        0.4519579824579369,
        0.5746157670044628,
        0.6539060041816466,
        0.7125004794185166,
        0.7152273374678139,
        0.666960263186802,
        0.57296016264855,
        0.4479322819018114,
        0.330131090709707,
        0.23081079259517157,
        0.16136204383095426,
        0.13058369902570988,
        0.10620542199069463,
        0.09578043562852234,
        0.0967404307133189,
        0.09927995248636683,
        0.07665120860011655,
        0.048066249122617574,
        0.024056603035882848,
        0.009272702561305062,
        0.0053076880111858115,
        0.004993578212243698,
        0.0042049870696637,
        0.0041287321567875426,
        0.0034989882128208614,
        0.0019357281296720034,
        0.00001129702015791953,
        0.0011335503221878616
      ],
      "range": 1
    }
  }
]
