    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,2 back ultra wide camera / prf-solomatov-pred-iphone13-2-back-ultra-wide-camera-cf50c1693eaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,2 back ultra wide camera / prf-solomatov-pred-iphone13-2-back-ultra-wide-camera-cf50c1693eaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26715383 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26715383; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016269396923862183,
        0.025198882606324604,
        0.024894698309210095,
        0.0004349627927849659,
        0.00002367704180022424,
        0.00002114702491819039,
        0.02975987654753069,
        0.06631306764346219,
        0.11270696362466524,
        0.11665845479362959,
        0.09931402817620097,
        0.0736378662435796,
        0.04433479018436681,
        0.000019695880085267728,
        0.00024150014993234425,
        0.00039160859494322055,
        0.004887621487590128,
        0.22548061541921374,
        0.6207029111280195,
        0.7982324266135358,
        0.7581007915926192,
        0.6805652758188045,
        0.5863789787329645,
        0.5102355448170068,
        0.44236690898273856,
        0.36374047117348085,
        0.2865630636850687,
        0.1937491968578553,
        0.10747612340051423,
        0.042431055545787986,
        0.03440161797418364
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,2 back ultra wide camera / prf-solomatov-pred-iphone13-2-back-ultra-wide-camera-cf50c1693eaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,2 back ultra wide camera / prf-solomatov-pred-iphone13-2-back-ultra-wide-camera-cf50c1693eaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26715383 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26715383; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.018377357719333468,
        0.030739375886918788,
        0.05875619675750111,
        0.09697230243713895,
        0.13788552460580483,
        0.1700369895501779,
        0.2180711128116711,
        0.3096451958034815,
        0.4222845167520151,
        0.5428449594003576,
        0.6813842047482532,
        0.8453170968950736,
        0.9596600580272422,
        1,
        0.985266503572118,
        0.9295549683865659,
        0.8443374365997299,
        0.712036582069589,
        0.5567472118966066,
        0.4192829090266084,
        0.3163432843167549,
        0.23359710021750393,
        0.17905963766269045,
        0.12824149292563017,
        0.08585356983278136,
        0.04898977866048187,
        0.03261233050636033,
        0.014301713735490898,
        0.005646831640033011,
        0.007859757428894058,
        0.0021151929583042104
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,2 back ultra wide camera / prf-solomatov-pred-iphone13-2-back-ultra-wide-camera-cf50c1693eaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / iPhone13,2 back ultra wide camera / prf-solomatov-pred-iphone13-2-back-ultra-wide-camera-cf50c1693eaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26715383 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26715383; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04890589440548167,
        0.11715864226988625,
        0.2738288648154511,
        0.4576968258325176,
        0.5778220360905925,
        0.6576777881118157,
        0.7163829917766854,
        0.7160677052617962,
        0.6640476387705166,
        0.5600016664556148,
        0.4289333602291983,
        0.30762680812025045,
        0.20963124503960884,
        0.14276341836461787,
        0.11594279221076488,
        0.09516991016000033,
        0.08817919623312158,
        0.09389758327627196,
        0.10212633298201265,
        0.08253960648814206,
        0.0513728551074862,
        0.02559087137174863,
        0.008898828064714627,
        0.004399560358165182,
        0.0036960671684924005,
        0.004070135172683094,
        0.0034425390794509667,
        0.0035903421635392614,
        0.001850719340239292,
        0.0005676278344952045,
        0.001836839471850357
      ],
      "range": 1
    }
  }
]