    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta DiMAGE A200 / prf-solomatov-pred-konica-minolta-dimage-a200-acf79a565d44@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta DiMAGE A200 / prf-solomatov-pred-konica-minolta-dimage-a200-acf79a565d44@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000532702735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28233245; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011117750297565865,
        0.022513077635438854,
        0.02916697545073277,
        0.007342037547710897,
        0.03095533788752811,
        0.043235224210953355,
        0.04878096248650805,
        0.0449121666409695,
        0.043291121682671144,
        0.03281140364698368,
        0.018593633059182532,
        0.013751449010540866,
        0.024283646276143326,
        0.026949273454043274,
        0.023631086527799248,
        0.03583338765088011,
        0.07347302969298378,
        0.21201490380602786,
        0.42971653233381546,
        0.5481372643479735,
        0.5226779050725483,
        0.4697459156604267,
        0.3969695666317515,
        0.3375929396214702,
        0.28030765791356965,
        0.22854426240576148,
        0.1778807612669519,
        0.120815329798971,
        0.0725846463774095,
        0.030077396859367517,
        0.01897254864914445
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta DiMAGE A200 / prf-solomatov-pred-konica-minolta-dimage-a200-acf79a565d44@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta DiMAGE A200 / prf-solomatov-pred-konica-minolta-dimage-a200-acf79a565d44@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000532702735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28233245; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01982351842659248,
        0.031052494510137026,
        0.06301190965945762,
        0.10897475694444286,
        0.14544311107831792,
        0.1629094359425485,
        0.20516263254773645,
        0.29767801617214484,
        0.409176571656334,
        0.533546678819272,
        0.689546937307419,
        0.8639102485698102,
        0.9734413046092947,
        1,
        0.9598814630949619,
        0.8776473177438351,
        0.7627910085635367,
        0.6033537823192033,
        0.42685331936968585,
        0.28000212551442427,
        0.17213370702989803,
        0.09708973454149823,
        0.06146335995029972,
        0.03449259551992694,
        0.01414728866182403,
        0.0003030748004837777,
        0.000007410558046341853,
        0.000002158024914753099,
        0.000012037696985780207,
        0.000020290730286946818,
        0.000014965182869647873
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta DiMAGE A200 / prf-solomatov-pred-konica-minolta-dimage-a200-acf79a565d44@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Konica Minolta DiMAGE A200 / prf-solomatov-pred-konica-minolta-dimage-a200-acf79a565d44@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000532702735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28233245; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06154867488664515,
        0.15151877019363552,
        0.34664530954132095,
        0.5543905239504736,
        0.7091748567078536,
        0.8222933385407484,
        0.9004867196070817,
        0.9092160806064669,
        0.8565347334026486,
        0.7079945096279081,
        0.5189988363009636,
        0.33033804512319836,
        0.17699549897783487,
        0.07567043037383765,
        0.04310350597122096,
        0.02585490245469642,
        0.02990163717327873,
        0.034972809692473,
        0.033108015006349106,
        0.023992064325921145,
        0.013772609323984306,
        0.005103756866516296,
        0.0005042196622479816,
        0.000010186808865795995,
        0.000011441857418444107,
        0.00002750948023808866,
        0.00001763980393906674,
        0.00002436683674305915,
        0.000012707074835316433,
        0.00002190179004743614,
        0.001045678262832143
      ],
      "range": 1
    }
  }
]