    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf AFi 54S / prf-solomatov-pred-leaf-afi-54s-2f0be4a953ef@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf AFi 54S / prf-solomatov-pred-leaf-afi-54s-2f0be4a953ef@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27211034 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27211034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010766893312470228,
        0.016666268543856142,
        0.01151830356758953,
        0.0003122579612373422,
        0.0000940319357213695,
        0.0001831079443728599,
        0.00011677799527941497,
        0.000028014184980989697,
        0.000053715015019274896,
        0.005621039979590632,
        0.037608986119380836,
        0.0932431895090793,
        0.15215982604703665,
        0.18703462720306768,
        0.19038558769946046,
        0.20809439288488632,
        0.266127828880005,
        0.45983537413535996,
        0.6958326537683206,
        0.7620809999355408,
        0.6982631384018704,
        0.6007478436872337,
        0.499537099545721,
        0.4140982294167873,
        0.33195827839544795,
        0.25275478322506967,
        0.19022832796431036,
        0.12260581497932052,
        0.0638701748709733,
        0.028395477364072233,
        0.016237229353357172
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf AFi 54S / prf-solomatov-pred-leaf-afi-54s-2f0be4a953ef@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf AFi 54S / prf-solomatov-pred-leaf-afi-54s-2f0be4a953ef@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27211034 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27211034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.019756176850905405,
        0.02974122556313001,
        0.049780544906893286,
        0.06825048250647145,
        0.08847146345118675,
        0.12430145065417213,
        0.1933656104358254,
        0.324893093000435,
        0.4834858168197504,
        0.6190378506013406,
        0.7580771462047344,
        0.9034625439077397,
        0.9899643284411757,
        1,
        0.9565856630071463,
        0.8699476102231176,
        0.7608851615120542,
        0.6332572661516648,
        0.500302671335459,
        0.3528797913375875,
        0.2094454036550026,
        0.10553394259108272,
        0.05823806621975482,
        0.04653589055086991,
        0.04622366794293815,
        0.04781219265684648,
        0.05868785802112481,
        0.04057116866635792,
        0.02355624192744752,
        0.014538041443041085,
        0.012143953074330067
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf AFi 54S / prf-solomatov-pred-leaf-afi-54s-2f0be4a953ef@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf AFi 54S / prf-solomatov-pred-leaf-afi-54s-2f0be4a953ef@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27211034 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27211034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04159895210156292,
        0.10154874673266734,
        0.2472360293254567,
        0.43799652743809736,
        0.5555709496375625,
        0.6190379241009364,
        0.66230948812897,
        0.6555245199429026,
        0.6060895003107931,
        0.5326896434733057,
        0.4451682725470851,
        0.3731739852296682,
        0.31252549976601407,
        0.2825046854154825,
        0.2718284060796808,
        0.2621552712770856,
        0.2426974660352855,
        0.1842755663015231,
        0.11359299687031371,
        0.07110229622292193,
        0.053977970848149315,
        0.03910207160815719,
        0.024084046199787924,
        0.005776396810205742,
        0.003035271059526808,
        0.001749929275013952,
        0.0009282901561182863,
        0.0017229014891532604,
        0.0020054908608030113,
        0.0013406581315506055,
        0.0005490336383395059
      ],
      "range": 1
    }
  }
]