    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Credo 60 / prf-solomatov-pred-leaf-credo-60-caa48a0c89b5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Credo 60 / prf-solomatov-pred-leaf-credo-60-caa48a0c89b5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000527359132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27950034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01673521128811507,
        0.02862700440154969,
        0.019317934716746935,
        0.00049050749084998,
        0.00021735933796587282,
        0.0027609382514525746,
        0.0037712224701003786,
        0.0183552940039129,
        0.06301406712957845,
        0.07143781803117459,
        0.07525395425279269,
        0.0942190612256816,
        0.11636251807559381,
        0.12515340768458455,
        0.11838757446525759,
        0.13555871686791313,
        0.19628691366580397,
        0.3806774636707626,
        0.6041704944641201,
        0.6635920395587573,
        0.5988589763432847,
        0.5138024108471215,
        0.4227036481855327,
        0.34592329672163924,
        0.28353827762785544,
        0.2152314326894365,
        0.1617470719030578,
        0.10364319728769208,
        0.05556354737297615,
        0.024717556201609057,
        0.013587688147867216
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Credo 60 / prf-solomatov-pred-leaf-credo-60-caa48a0c89b5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Credo 60 / prf-solomatov-pred-leaf-credo-60-caa48a0c89b5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000527359132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27950034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.022086907747589857,
        0.036142061798477995,
        0.06638880325989346,
        0.099590197278472,
        0.13511781498109351,
        0.16826252240774456,
        0.22522158742586706,
        0.3374341466754719,
        0.4783145576853324,
        0.6094480213643871,
        0.7503467294529946,
        0.9036987421420472,
        0.9922683739297612,
        1,
        0.9457522279195055,
        0.8536450087388737,
        0.7344426786488244,
        0.6001200847172431,
        0.46777741135213424,
        0.32624243131359437,
        0.19483657419999323,
        0.10132209323322011,
        0.05735504749008015,
        0.04441249820735942,
        0.04172498736942502,
        0.04139817014451299,
        0.04732455808732675,
        0.032028192315583744,
        0.019844387782687285,
        0.01171034612923076,
        0.007576706351872673
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Credo 60 / prf-solomatov-pred-leaf-credo-60-caa48a0c89b5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Credo 60 / prf-solomatov-pred-leaf-credo-60-caa48a0c89b5@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000527359132075 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27950034; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05973331186287645,
        0.1416557690404101,
        0.32474307502077593,
        0.5416020569769877,
        0.6699549119754852,
        0.7382139475513101,
        0.7749331344828324,
        0.7461385107682105,
        0.6649244863172618,
        0.5475251497375785,
        0.41422176788765264,
        0.30525228558878725,
        0.2228837861163246,
        0.18075334004960425,
        0.17333926167701288,
        0.17098551488507865,
        0.16958009309960564,
        0.14739551037096377,
        0.11114863285108631,
        0.08309754167934956,
        0.06996919699632566,
        0.05522924036162673,
        0.038193238726212,
        0.018749799095851626,
        0.0031062169503979853,
        0.0005651119620765455,
        0.00006656463795140262,
        0.0000018301388732243864,
        0.000012644416534835825,
        0.0002814628968333951,
        0.0006150321917829714
      ],
      "range": 1
    }
  }
]