    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Valeo 6 / prf-solomatov-pred-leaf-valeo-6-8ecc0afbc214@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Valeo 6 / prf-solomatov-pred-leaf-valeo-6-8ecc0afbc214@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516569735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27378196; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011246139866191331,
        0.022409337137853928,
        0.04288695377118625,
        0.049637594482035065,
        0.09986917907560122,
        0.1153049869806372,
        0.11869900801797674,
        0.1064497168756465,
        0.10123338735807623,
        0.10024916699614331,
        0.11354046110269646,
        0.1350284671501251,
        0.15705765386328707,
        0.17150722786848338,
        0.16537805134069838,
        0.17353502108027863,
        0.20624933458518802,
        0.3081207261274244,
        0.45054003104740975,
        0.5174278335967715,
        0.48022348087994304,
        0.4229223790670958,
        0.35318293009046203,
        0.29210916147252636,
        0.2331407451252449,
        0.18054141444415223,
        0.13637489294345206,
        0.09041775269721498,
        0.05090790936657167,
        0.021008308788941898,
        0.014836420298004398
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Valeo 6 / prf-solomatov-pred-leaf-valeo-6-8ecc0afbc214@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Valeo 6 / prf-solomatov-pred-leaf-valeo-6-8ecc0afbc214@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516569735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27378196; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02360990811812436,
        0.03416539160596549,
        0.05259228148108044,
        0.06487796007365658,
        0.07727121810894533,
        0.10541174168102399,
        0.17542552554372573,
        0.32319777931811755,
        0.4925085114568298,
        0.6342417669945554,
        0.7773503791119035,
        0.9225842417111205,
        0.9987809277134256,
        1,
        0.9461212275420705,
        0.8569620046285272,
        0.7463145998683456,
        0.6071810427718184,
        0.46130073727282833,
        0.320247817531482,
        0.20822258035798508,
        0.12945785793179074,
        0.08669050316890031,
        0.05722746444269878,
        0.035732814650205585,
        0.018698995923055534,
        0.014133839305090544,
        0.004343343589532059,
        0.0014731556927314584,
        0.0031184487206481785,
        0.000007651530327272111
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Valeo 6 / prf-solomatov-pred-leaf-valeo-6-8ecc0afbc214@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leaf Valeo 6 / prf-solomatov-pred-leaf-valeo-6-8ecc0afbc214@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000516569735849 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27378196; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06369923597230438,
        0.14782562469891253,
        0.3408464985369066,
        0.5556735961678035,
        0.7014265932642164,
        0.8008177667285958,
        0.8687315644711675,
        0.8783165019501479,
        0.8416343893086796,
        0.7379164509045737,
        0.607089494866645,
        0.4832443607142491,
        0.3673505432234075,
        0.2888890633992101,
        0.23686560276462876,
        0.19024677686778724,
        0.14811622097275612,
        0.10538350593668605,
        0.0678775397110495,
        0.026134036908266805,
        0.00013077979340445463,
        0.00006768268723947992,
        0.000006869773528140139,
        0.000019346620364822952,
        0.00004733534420054557,
        0.00002561218271874226,
        0.00719303744815433,
        0.008536676657454638,
        0.006037239370852544,
        0.0019837337352136986,
        0.002014943826101617
      ],
      "range": 1
    }
  }
]