    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D Lux 7 / prf-solomatov-pred-leica-d-lux-7-a61bf20ffa32@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D Lux 7 / prf-solomatov-pred-leica-d-lux-7-a61bf20ffa32@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27869114 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27869114; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014449286044759084,
        0.021964996806141737,
        0.025069688257760903,
        0.0013853223679805536,
        0.0026255516052645232,
        0.01601949742643415,
        0.03576877973228714,
        0.050358497223844285,
        0.07669098127769688,
        0.07373300421391221,
        0.062408955663247855,
        0.054819686768657234,
        0.049418395575833524,
        0.03180203001789005,
        0.008108891800435421,
        0.009156620479574629,
        0.06747734427438203,
        0.27924504524973415,
        0.578551976930447,
        0.7129446239302764,
        0.6797053899883577,
        0.613335034619328,
        0.5228984315755427,
        0.4415558958924923,
        0.36466157481719724,
        0.2869956683947685,
        0.21928565795094887,
        0.1476991697690856,
        0.08190224490093227,
        0.03419258323031008,
        0.02217003382310611
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D Lux 7 / prf-solomatov-pred-leica-d-lux-7-a61bf20ffa32@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D Lux 7 / prf-solomatov-pred-leica-d-lux-7-a61bf20ffa32@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27869114 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27869114; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.0174090033863294,
        0.02850492125440371,
        0.05245687035475903,
        0.08298114177580242,
        0.11491927586933694,
        0.1427989529914729,
        0.18782803787734334,
        0.2789432057294681,
        0.3948619249252058,
        0.5128922290102226,
        0.6585511114562164,
        0.8330926128473262,
        0.9549072855348038,
        1,
        0.9819294219400014,
        0.9207934633300505,
        0.8233281115431226,
        0.6845005191051283,
        0.5323951453928532,
        0.38358971153514243,
        0.2613627042467156,
        0.16761263382825875,
        0.1206001023211574,
        0.0883229979969941,
        0.0636296797953462,
        0.04018075709188315,
        0.03487338348825872,
        0.01940469438676809,
        0.009893173137832799,
        0.01092623827223212,
        0.002349647929245257
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D Lux 7 / prf-solomatov-pred-leica-d-lux-7-a61bf20ffa32@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica D Lux 7 / prf-solomatov-pred-leica-d-lux-7-a61bf20ffa32@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27869114 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27869114; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.042810919643875296,
        0.10822449540376489,
        0.26063864104183576,
        0.4470230736434606,
        0.5702263085938074,
        0.6494953517359755,
        0.7103428548177025,
        0.7149319852794747,
        0.6681401138191907,
        0.5693422833607125,
        0.43271400734160403,
        0.3019835291498682,
        0.19195461326829408,
        0.12215769040953364,
        0.10053467792338142,
        0.09092804313764694,
        0.09393939470052762,
        0.09082229883590845,
        0.07354606967412025,
        0.05420124227845923,
        0.039930009974482865,
        0.025990649361870635,
        0.01062653803777185,
        0.000021066115341879905,
        0.00016666143387263766,
        0.00003061365711159673,
        0.00003213558206407279,
        0.000039132768985766825,
        0.00008527183174893899,
        0.00002663996063886351,
        0.0016125451637967394
      ],
      "range": 1
    }
  }
]