[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537517056604 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28488404; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01099637337528631,
        0.021400459862246528,
        0.02715947258333434,
        0.006610821477512598,
        0.028913921368912708,
        0.03281351169331134,
        0.030296630501491673,
        0.013808511836247029,
        0.005708817290478376,
        0.000056671283745155125,
        0.0001477002990409712,
        0.01757735265638223,
        0.047957962933863306,
        0.07024631846698046,
        0.07801142281012406,
        0.09568080306384566,
        0.14217460794373937,
        0.2686410712380045,
        0.44512364544462757,
        0.5339746674066914,
        0.5067972200197666,
        0.44533104549152414,
        0.3697009013596119,
        0.3034294852707355,
        0.2412089851979774,
        0.18208066206651877,
        0.13349975234793351,
        0.08438939425025066,
        0.04694968934191816,
        0.016664648393150735,
        0.00929745592527502
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537517056604 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28488404; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01992778437149375,
        0.028273701082882366,
        0.053389264812381036,
        0.08373581764445566,
        0.10570784639570927,
        0.11905392952944019,
        0.16533779880036986,
        0.2728434744066244,
        0.40031721912770774,
        0.5294537255457716,
        0.6872127227625668,
        0.8626561089592116,
        0.9755907587198259,
        1,
        0.9573154955466298,
        0.8701851896078011,
        0.7509108887903002,
        0.5976246095003943,
        0.43678732618172744,
        0.2895551788458995,
        0.1677433591342405,
        0.08096130731463726,
        0.045860654221320726,
        0.029122832206529,
        0.017880334634356843,
        0.011614314803584373,
        0.015228878260910522,
        0.008587713044813476,
        0.004066519383073321,
        0.006010781149380304,
        0.0005937423546587085
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica DIGILUX 3 / prf-solomatov-pred-leica-digilux-3-b3dc37de45e4@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000537517056604 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28488404; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.056274325862550954,
        0.14137252570657408,
        0.33436012721928143,
        0.558963636001544,
        0.7148580763533886,
        0.8137727913590542,
        0.8861379871705298,
        0.8936791914023624,
        0.8426681819089151,
        0.7129533225418414,
        0.5367749664038743,
        0.36176800010195276,
        0.21261694886587756,
        0.11847743383588634,
        0.08857075008874175,
        0.07609994451203246,
        0.0766454581585446,
        0.06285345711003566,
        0.03438562254651232,
        0.01698794621542345,
        0.01330301041083242,
        0.010518171142632595,
        0.000032688841147549924,
        0.00001871521562982341,
        0.00005183069536161099,
        0.000015116573039548085,
        0.0001016785211231485,
        0.000014327592545237684,
        0.00006220356096466478,
        0.00008487525742714144,
        0.0007926666733795066
      ],
      "range": 1
    }
  }
]
