[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 D / prf-solomatov-pred-leica-m10-d-2b7790b0fbc4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 D / prf-solomatov-pred-leica-m10-d-2b7790b0fbc4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27873716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27873716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009892715058157298,
        0.01849453800849517,
        0.018631215156242536,
        0.00011567768718028125,
        0.0000651678018101354,
        0.0015232257873331277,
        0.014170241958409853,
        0.02446484422816104,
        0.048336633694624716,
        0.04856100277408294,
        0.04676018798498199,
        0.05193451601501573,
        0.06510831207435708,
        0.06540624149288168,
        0.057709707596934695,
        0.06962361961354561,
        0.12187467218220922,
        0.2999810071968876,
        0.5488569231314547,
        0.6558190160221192,
        0.623430546540691,
        0.5578732667004285,
        0.47302232684009554,
        0.39438666878861794,
        0.3221668040242643,
        0.24792528559880572,
        0.18400268195313463,
        0.11635150117766861,
        0.06166307355646446,
        0.02375219005603702,
        0.013591587501286159
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 D / prf-solomatov-pred-leica-m10-d-2b7790b0fbc4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 D / prf-solomatov-pred-leica-m10-d-2b7790b0fbc4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27873716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27873716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016803642542673535,
        0.02476514649141148,
        0.04799304836140255,
        0.07420379112709623,
        0.100931529904373,
        0.12191506866181748,
        0.16645774104895095,
        0.2650021618933048,
        0.37978405893207784,
        0.5015922527157843,
        0.651593314648108,
        0.8317708338565264,
        0.9581262146747855,
        1,
        0.9793872837048351,
        0.9097288642820355,
        0.8069351786464353,
        0.6676175864029038,
        0.516350421307299,
        0.3639246736961803,
        0.23330188195933402,
        0.1331233087113322,
        0.08626840425582294,
        0.06404783990767504,
        0.04946317885996973,
        0.0361939416330424,
        0.03450626748152274,
        0.021451902932497414,
        0.010055820329087087,
        0.009735900659962238,
        0.002274363167078261
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 D / prf-solomatov-pred-leica-m10-d-2b7790b0fbc4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 D / prf-solomatov-pred-leica-m10-d-2b7790b0fbc4@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27873716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27873716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.044688329320712025,
        0.10615138648897765,
        0.25595065975415693,
        0.4464564932784707,
        0.5879210005583755,
        0.6800987353103547,
        0.7531691145880944,
        0.7770028581764986,
        0.7503958209231952,
        0.6590176925100335,
        0.5166922128359205,
        0.366932830197452,
        0.23140570851765874,
        0.138376791956982,
        0.10602824180313813,
        0.08893168747216913,
        0.09339597203329474,
        0.08486983221038774,
        0.06570539428614398,
        0.053361805078303876,
        0.049204078135832344,
        0.045462138955566604,
        0.028409893392040014,
        0.0045303604298759445,
        0.00003986137693302178,
        0.00004300617470594879,
        0.00009544137566731325,
        0.000025584244669781384,
        0.000020001889952527322,
        0.0001239388390123513,
        0.000782096617472891
      ],
      "range": 1
    }
  }
]
