    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 P / prf-solomatov-pred-leica-m10-p-ffebe408bb4e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 P / prf-solomatov-pred-leica-m10-p-ffebe408bb4e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27861705 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27861705; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009880431222712321,
        0.01957079188082711,
        0.018820179884899365,
        0.00022086117845264674,
        0.00003508021494018403,
        0.0007341602389372798,
        0.013314794625813461,
        0.025001094871975712,
        0.0476021729467023,
        0.048588447835478846,
        0.04498189540087372,
        0.05227636284283392,
        0.06352450074394228,
        0.06526555715093531,
        0.05686653419092623,
        0.0710441195181702,
        0.12700811382505126,
        0.3098235014691312,
        0.5535089112457404,
        0.6567565050308299,
        0.620804218550157,
        0.5575988978420381,
        0.47259850034303363,
        0.3932049384630266,
        0.31898762118111584,
        0.24584534219998386,
        0.1835735573253683,
        0.11522747800251279,
        0.06128166599998098,
        0.023733739553986378,
        0.011518277865622368
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 P / prf-solomatov-pred-leica-m10-p-ffebe408bb4e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 P / prf-solomatov-pred-leica-m10-p-ffebe408bb4e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27861705 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27861705; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016220498709608764,
        0.025463500169856802,
        0.04760082342412283,
        0.07580648420475346,
        0.10055208753376724,
        0.12194173328588472,
        0.16660290531394256,
        0.26379230919285096,
        0.384130045164142,
        0.5064874529394379,
        0.6573219406350043,
        0.8334773482096663,
        0.9571872934553001,
        1,
        0.9783348506489463,
        0.9113572195240744,
        0.8070124925951231,
        0.6679584038378126,
        0.5168303231980959,
        0.36493685508478396,
        0.2304479930427804,
        0.13463928356143318,
        0.0876273042155891,
        0.06415679873144878,
        0.04947695412035983,
        0.03639464454885299,
        0.0359136851100821,
        0.02116362046041332,
        0.010425667058064107,
        0.010275517955559432,
        0.0011794320196843661
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 P / prf-solomatov-pred-leica-m10-p-ffebe408bb4e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA M10 P / prf-solomatov-pred-leica-m10-p-ffebe408bb4e@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27861705 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27861705; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04312051254580436,
        0.11024263949388598,
        0.26695706526215823,
        0.45612014770811765,
        0.5882038805593557,
        0.6812260771550055,
        0.7542094067825355,
        0.7744943103805026,
        0.7475293059057226,
        0.6537745267204574,
        0.5099363804189299,
        0.3603542568554222,
        0.22552581042689243,
        0.13511983563102115,
        0.10476596102069131,
        0.08929681080177973,
        0.09127115515723105,
        0.08557319087256146,
        0.06567729433643778,
        0.0515902418750037,
        0.05052068421512611,
        0.04447879266541657,
        0.028681708459694054,
        0.003651875217256087,
        0.000011726303182091694,
        0.0000030193414222137523,
        0.00002250580429302514,
        0.00005111756441323315,
        0.00008310444030614782,
        0.000426007834050357,
        0.00042595329323887396
      ],
      "range": 1
    }
  }
]