[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital / prf-solomatov-pred-leica-m8-digital-4bf9931db570@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital / prf-solomatov-pred-leica-m8-digital-4bf9931db570@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2713379 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2713379; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.009728319560223617,
        0.01972537931486902,
        0.03451054939247337,
        0.025195559853599513,
        0.06446072222125991,
        0.0828488979976627,
        0.09010580534455379,
        0.08230281505090146,
        0.07748454970721008,
        0.06907193208173278,
        0.056101289204346316,
        0.04745161291511432,
        0.045165120685315245,
        0.03223462700934886,
        0.013849586069620204,
        0.009282884919504426,
        0.04937169484985326,
        0.22324307809561433,
        0.4838463775241129,
        0.636210680483633,
        0.623886084472534,
        0.5674980531654443,
        0.49213618886266897,
        0.4309381033759014,
        0.37274184697382856,
        0.3173580616640727,
        0.2578935342243011,
        0.186123317089135,
        0.11178924875588703,
        0.04550679798140989,
        0.03637324162971704
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital / prf-solomatov-pred-leica-m8-digital-4bf9931db570@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital / prf-solomatov-pred-leica-m8-digital-4bf9931db570@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2713379 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2713379; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016100437867323365,
        0.02494646711719962,
        0.0472231081614474,
        0.07645899817165239,
        0.09793167117457605,
        0.11668224380007364,
        0.16668998322755502,
        0.2736216577190285,
        0.402960717983002,
        0.5350690043668798,
        0.685354165415152,
        0.8555416696303759,
        0.9654288619466723,
        1,
        0.9791279802784646,
        0.9151744743362427,
        0.8208716511773696,
        0.6781923940592154,
        0.516762420583339,
        0.3732363374228222,
        0.26260866616864065,
        0.18469582760093592,
        0.1348876069284829,
        0.08938869210677904,
        0.05072439935593222,
        0.022176961640817592,
        0.008454902540338078,
        0.00003341662370055934,
        0.00000963621373940021,
        0.0014387192132024314,
        0.000204555301710524
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital / prf-solomatov-pred-leica-m8-digital-4bf9931db570@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital / prf-solomatov-pred-leica-m8-digital-4bf9931db570@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2713379 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2713379; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04675803122232463,
        0.11437801353957555,
        0.2684676338985449,
        0.45431594333117487,
        0.5962537117004296,
        0.70344301330555,
        0.782090891099253,
        0.8116370768698364,
        0.7867450142423892,
        0.6881570175047422,
        0.5507006208863561,
        0.4141189085638239,
        0.29134024402783393,
        0.20231720301513353,
        0.15311304465760217,
        0.11111555002084117,
        0.08287137550633361,
        0.06832312773114262,
        0.0638019790084614,
        0.03953734808148806,
        0.00005739364828872044,
        0.000051980655853826537,
        0.00005041259624991569,
        0.000006135915034353844,
        0.000026259088759808338,
        0.011258123174093998,
        0.020569340294886926,
        0.019734362947454075,
        0.012332316274283835,
        0.004044308222330901,
        0.006331080177151809
      ],
      "range": 1
    }
  }
]
