    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital Camera / prf-solomatov-pred-leica-m8-digital-camera-5a055a6d784d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital Camera / prf-solomatov-pred-leica-m8-digital-camera-5a055a6d784d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00051223754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2714859; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.014186576208930187,
        0.027864903373367486,
        0.04287961732082587,
        0.029139237664978907,
        0.07841777217360257,
        0.09891670216063196,
        0.10343723351666737,
        0.09027764194140628,
        0.08511287518369585,
        0.07465487210517063,
        0.05979596804106585,
        0.05085984749332557,
        0.04651745400179021,
        0.029789024034029027,
        0.009972743929283663,
        0.0052704158920156875,
        0.04817879097430632,
        0.22328949486394767,
        0.4570286967719705,
        0.5767116731554701,
        0.5522782380226745,
        0.4948181319974236,
        0.42031957425128086,
        0.36179949466462685,
        0.30561028445676186,
        0.2551609846744555,
        0.20383277955157378,
        0.14030419094412933,
        0.08312645740696359,
        0.03175954305706036,
        0.020417532396973206
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital Camera / prf-solomatov-pred-leica-m8-digital-camera-5a055a6d784d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital Camera / prf-solomatov-pred-leica-m8-digital-camera-5a055a6d784d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00051223754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2714859; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.021788167543876125,
        0.033640944466603435,
        0.06021724626442496,
        0.09617748874996179,
        0.11993559677249603,
        0.13936154417022928,
        0.19715508886144892,
        0.31349405450491125,
        0.45002598815137973,
        0.5829372098559243,
        0.7304546534460905,
        0.8928240854945205,
        0.9856456151979786,
        1,
        0.9586220786338361,
        0.8788653246314584,
        0.7723315760992165,
        0.6242028226427939,
        0.4636932367008938,
        0.32997485133307264,
        0.23206049743283172,
        0.15971243297186843,
        0.11742628699935215,
        0.07712832769700917,
        0.04410602280588053,
        0.020068876958534213,
        0.008117591485609492,
        0.000019215404446968532,
        0.000008989201389139418,
        0.0026310830096169992,
        0.00007183148895972656
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital Camera / prf-solomatov-pred-leica-m8-digital-camera-5a055a6d784d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica M8 Digital Camera / prf-solomatov-pred-leica-m8-digital-camera-5a055a6d784d@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.00051223754717 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2714859; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06130783983624932,
        0.14281945595180218,
        0.32895298745586,
        0.5524009577027414,
        0.7171417959794263,
        0.8278857297725017,
        0.90368615268145,
        0.9122768320878198,
        0.8692325350352755,
        0.7436688390875278,
        0.5831064154713007,
        0.4270910474973643,
        0.29378174109452976,
        0.19660912039999132,
        0.145876004364622,
        0.10210742034518519,
        0.07561002326192894,
        0.06553014355441664,
        0.061409446284700055,
        0.03561685380408151,
        0.0000886489909175148,
        0.000058214525152497276,
        0.000011833516156349068,
        0.0000030010964526281895,
        0.000021425889947231145,
        0.009175458405305481,
        0.016886212891886666,
        0.015173450166755862,
        0.009862452026812008,
        0.0030113208270762357,
        0.002446264586327109
      ],
      "range": 1
    }
  }
]