[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA SL (Typ 601) / prf-solomatov-pred-leica-sl-typ-601-00c7d9b26243@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA SL (Typ 601) / prf-solomatov-pred-leica-sl-typ-601-00c7d9b26243@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2781119 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2781119; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.010965584356512612,
        0.017942917940584346,
        0.01992701498929028,
        0.000182272520521416,
        0.00021786022820310816,
        0.0018851239375229896,
        0.019327637544456027,
        0.030199524004546365,
        0.054153917901391485,
        0.057482466589887024,
        0.05147969576274873,
        0.05273446048155436,
        0.05953730135244122,
        0.05225361805805504,
        0.035208779271940535,
        0.03859194806119407,
        0.08512969060295514,
        0.28275351036758944,
        0.5676596003263433,
        0.6916746460687226,
        0.6591422373512243,
        0.5951991985959608,
        0.5060675936556472,
        0.4252103200186687,
        0.35028334278396567,
        0.2746058331196903,
        0.20652105501418672,
        0.13493357889396318,
        0.0728781256753127,
        0.027965201417127418,
        0.01936977525952683
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA SL (Typ 601) / prf-solomatov-pred-leica-sl-typ-601-00c7d9b26243@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA SL (Typ 601) / prf-solomatov-pred-leica-sl-typ-601-00c7d9b26243@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2781119 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2781119; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.016867604730326172,
        0.025050423948058315,
        0.049032303184437624,
        0.07765147769656745,
        0.10554566345417077,
        0.12918501509644137,
        0.1776698156389568,
        0.2769358484840095,
        0.39384548449742707,
        0.5137995173885044,
        0.6613051796776764,
        0.8381816096326694,
        0.9583023955465407,
        1,
        0.9778074940338762,
        0.9113459366535556,
        0.8098614981955105,
        0.6659041198884333,
        0.5071523368831035,
        0.3572443681841733,
        0.23403367493444183,
        0.1417062700301569,
        0.09717818619052258,
        0.06850098827126778,
        0.0475101029477703,
        0.02893048805175183,
        0.025511792195875113,
        0.011913151145276414,
        0.005256516172087566,
        0.008163435653059074,
        0.0001401344674571638
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA SL (Typ 601) / prf-solomatov-pred-leica-sl-typ-601-00c7d9b26243@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA SL (Typ 601) / prf-solomatov-pred-leica-sl-typ-601-00c7d9b26243@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2781119 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2781119; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04444333737607056,
        0.10753272333905883,
        0.256724232224511,
        0.44384220883752185,
        0.5780434062692031,
        0.6653285242379057,
        0.7329314207698411,
        0.7503633249781831,
        0.7181957694007339,
        0.6271470224754855,
        0.49018441857396244,
        0.35196455095952384,
        0.22612782840288387,
        0.13912953742720105,
        0.10618142193843556,
        0.08553232709567624,
        0.0857430911802048,
        0.08014946501749835,
        0.06993319595457799,
        0.05579786409714938,
        0.04294074795073493,
        0.03092147081804122,
        0.01509350013429846,
        0.0015448824735654965,
        0.00003354074385166546,
        0.00008952805687207198,
        0.00013053635604948942,
        0.0000450615993058909,
        0.0005856335884944154,
        0.00004760804913417944,
        0.002137168276510282
      ],
      "range": 1
    }
  }
]
