[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA T (Typ 701) / prf-solomatov-pred-leica-t-typ-701-d0ddd77120b8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA T (Typ 701) / prf-solomatov-pred-leica-t-typ-701-d0ddd77120b8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530123716981 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28096557; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.012124687679703958,
        0.02511639851242358,
        0.03358967763847194,
        0.014340904292427036,
        0.0424125311057605,
        0.060377268922230505,
        0.069857188025472,
        0.0710053843888144,
        0.0797307596561861,
        0.07325023286152615,
        0.06519439310660022,
        0.06338174209073962,
        0.06724390787044175,
        0.0650130476840988,
        0.058616862240847195,
        0.06761895681899581,
        0.10737659968698046,
        0.24144728055831732,
        0.4253198139740654,
        0.5180409549945563,
        0.4923136964195767,
        0.44149378790608335,
        0.37005725785937676,
        0.306837869228592,
        0.2463251658379352,
        0.1905429529483466,
        0.1414432953151843,
        0.09147578298459375,
        0.052356516023109374,
        0.020892655740650027,
        0.012947057036205538
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA T (Typ 701) / prf-solomatov-pred-leica-t-typ-701-d0ddd77120b8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA T (Typ 701) / prf-solomatov-pred-leica-t-typ-701-d0ddd77120b8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530123716981 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28096557; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.02194174279966047,
        0.033803577306122094,
        0.06635805462874736,
        0.10490237547942344,
        0.1410907575388556,
        0.17013054667951744,
        0.22461030955562958,
        0.32672252939079927,
        0.4444679860299846,
        0.5615386168170727,
        0.70664768996429,
        0.8748008651931629,
        0.9776093527703822,
        1,
        0.9574859995465979,
        0.8735473757999471,
        0.761423407806566,
        0.6139683011132309,
        0.4575214383888316,
        0.3165227567906666,
        0.20368767366525847,
        0.12312840032438092,
        0.0813675342108012,
        0.05384712208405588,
        0.033100233375569825,
        0.018025483779437405,
        0.014932367136440928,
        0.00576062235944468,
        0.002028636808438423,
        0.0042970521830914335,
        0.0005988025136725064
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA T (Typ 701) / prf-solomatov-pred-leica-t-typ-701-d0ddd77120b8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LEICA T (Typ 701) / prf-solomatov-pred-leica-t-typ-701-d0ddd77120b8@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000530123716981 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.28096557; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.06036827626246163,
        0.1470531471776886,
        0.3359673259541916,
        0.5442378783196617,
        0.6933872433033506,
        0.799676603317149,
        0.8758866015535981,
        0.897386229224653,
        0.8666590573416759,
        0.750362695503864,
        0.5811053347212614,
        0.40377241477191195,
        0.24172851567652112,
        0.12539100431415848,
        0.07175638769679278,
        0.03564820700272991,
        0.02471534933723628,
        0.02688601467644769,
        0.032439034839012844,
        0.027112702149090086,
        0.011197020575629012,
        0.00012765579695084474,
        0.000043719595280177974,
        0.00003481475285727137,
        0.00020815067472057164,
        0.0063437934898790405,
        0.006809385339752957,
        0.00637651323123636,
        0.003818518749677491,
        0.0015433758549547342,
        0.0010735588349846566
      ],
      "range": 1
    }
  }
]
