    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 3 / prf-solomatov-pred-leica-v-lux-3-9cd998a63aaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 3 / prf-solomatov-pred-leica-v-lux-3-9cd998a63aaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.262716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.262716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015158977755446947,
        0.02566190639321549,
        0.02370295109547953,
        0.00002028269500144643,
        0.000007700157965255257,
        0.004345055877830052,
        0.03644653922867279,
        0.07544810365565859,
        0.12589572770596383,
        0.13733748610667032,
        0.12665955632698425,
        0.10898522358744804,
        0.08084892050731589,
        0.027110033648502566,
        0.000007951624567974544,
        0.000008094424397448195,
        0.00005464534516359871,
        0.263855798657105,
        0.6519763546948035,
        0.8140265914523669,
        0.7713204372782777,
        0.6938201327669423,
        0.5990928607317407,
        0.5246635530382618,
        0.46030013398498754,
        0.38986464471139937,
        0.31371781695823625,
        0.21983579987515034,
        0.12378667458396138,
        0.05298671569299167,
        0.03884396077893999
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 3 / prf-solomatov-pred-leica-v-lux-3-9cd998a63aaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 3 / prf-solomatov-pred-leica-v-lux-3-9cd998a63aaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.262716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.262716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01923713972502626,
        0.03208836538315139,
        0.06316568842400158,
        0.10222439059668996,
        0.1455879352608901,
        0.1900719484157798,
        0.25619893725543935,
        0.36378214497784683,
        0.49387528738257286,
        0.613137494480732,
        0.7390904627049742,
        0.8840233560194278,
        0.9766769819881546,
        1,
        0.9769269857945461,
        0.9134236209442896,
        0.8254828027223313,
        0.6995156366570745,
        0.5629117373894243,
        0.4303916015773687,
        0.31903831513878106,
        0.23040365261346854,
        0.17387732380212853,
        0.1219065835350721,
        0.08485604987895674,
        0.055110880190015074,
        0.03901886828362185,
        0.020859474108923703,
        0.012014461243319783,
        0.008120239345909651,
        0.003771375173190822
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 3 / prf-solomatov-pred-leica-v-lux-3-9cd998a63aaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Leica V LUX 3 / prf-solomatov-pred-leica-v-lux-3-9cd998a63aaf@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.262716 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.262716; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04601626471170389,
        0.10806245908128931,
        0.2582989235524292,
        0.4462293122611489,
        0.562804244888016,
        0.6312081487233362,
        0.6804866852418581,
        0.6789795825149592,
        0.6328328308896298,
        0.555901353552886,
        0.45226655399747256,
        0.3607105543628861,
        0.2765611154250217,
        0.2119294066596629,
        0.17058418215868087,
        0.1330230515080924,
        0.10316812070829336,
        0.0932952313524871,
        0.09248897288326557,
        0.0659059288357009,
        0.028327111405472068,
        0.007349480427533916,
        0.00256887779960109,
        0.004288095129341189,
        0.01240165806422144,
        0.016978495409491617,
        0.019874427138050214,
        0.015472464562493337,
        0.008158048995873872,
        0.0037053373224318273,
        0.0030327646584144092
      ],
      "range": 1
    }
  }
]