[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LG V50S ThinQ Front Camera / prf-solomatov-pred-lg-v50s-thinq-front-camera-9b7ae9c15a08@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LG V50S ThinQ Front Camera / prf-solomatov-pred-lg-v50s-thinq-front-camera-9b7ae9c15a08@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26730454 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26730454; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.013526794943325692,
        0.024784846527485093,
        0.023368087949422786,
        0.00002389221672029963,
        0.000018411346099845517,
        0.0017395782727820488,
        0.03131137615545176,
        0.062159872032102416,
        0.1058859755992173,
        0.11449432920219015,
        0.10406177164069119,
        0.09163420119987488,
        0.07368326778138523,
        0.03544760594040041,
        0.000033984319907174046,
        0.00008833593323929329,
        0.013778057043101475,
        0.26377726319201317,
        0.640610518624188,
        0.8043853650970538,
        0.7556479586916107,
        0.6801375315211631,
        0.5830573622131522,
        0.5046502390120273,
        0.43241222165549453,
        0.3522027534586581,
        0.2749413459270089,
        0.1857793137370581,
        0.10121298351311206,
        0.03882628405787646,
        0.034743719653994656
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LG V50S ThinQ Front Camera / prf-solomatov-pred-lg-v50s-thinq-front-camera-9b7ae9c15a08@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LG V50S ThinQ Front Camera / prf-solomatov-pred-lg-v50s-thinq-front-camera-9b7ae9c15a08@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26730454 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26730454; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01812613807457217,
        0.03037534267094753,
        0.05784743498931968,
        0.09092191999432557,
        0.12581609350892434,
        0.16292162490019813,
        0.22328047626875325,
        0.33088446608501304,
        0.46329104623512946,
        0.587079216836347,
        0.7219749802977533,
        0.8746278682733934,
        0.9730285164629079,
        1,
        0.9762580912393034,
        0.9128495909571908,
        0.8235145950008931,
        0.6908740495017406,
        0.5402300686699897,
        0.4012964762962874,
        0.29006843654806613,
        0.2032634537370746,
        0.14959938952028276,
        0.10506818926457441,
        0.07034142779617586,
        0.04284653002900737,
        0.027828416232661073,
        0.011704999847739213,
        0.006319138462818477,
        0.0086033331121125,
        0.0015543873665595056
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / LG V50S ThinQ Front Camera / prf-solomatov-pred-lg-v50s-thinq-front-camera-9b7ae9c15a08@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / LG V50S ThinQ Front Camera / prf-solomatov-pred-lg-v50s-thinq-front-camera-9b7ae9c15a08@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.26730454 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.26730454; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04675779169332478,
        0.11009070777473515,
        0.25825556498217356,
        0.44064283382541874,
        0.5575299993034163,
        0.6337560147687727,
        0.6858557284511517,
        0.6848267896983719,
        0.6380924543967715,
        0.5570886674801708,
        0.4483192092435093,
        0.35168860207162966,
        0.26663020388654834,
        0.20726389458256117,
        0.17266598614449272,
        0.14251033671182692,
        0.12100800831890099,
        0.1104104479482466,
        0.10777979304055219,
        0.08103655104398902,
        0.04334242134458323,
        0.01779967598006379,
        0.004353196170929234,
        0.004921109084043242,
        0.009120150746410817,
        0.012275091549137175,
        0.013529078855151507,
        0.01062141144329236,
        0.005383115453257921,
        0.001942507972367398,
        0.0037385275985211477
      ],
      "range": 1
    }
  }
]
