[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2847007 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847007; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.007030541196421366,
        0.01305920006519127,
        0.025476658821000444,
        0.025380682239277953,
        0.05470486373935857,
        0.06270167583009104,
        0.06002429920263632,
        0.042567419047441754,
        0.027732039296004544,
        0.017799099194346905,
        0.00992444521562469,
        0.013646119942803092,
        0.028104627069761336,
        0.04077742344855493,
        0.04746630408706407,
        0.06295103594757583,
        0.0995275002836312,
        0.20642707938547397,
        0.37076607117579974,
        0.48562785409379045,
        0.4792119935075678,
        0.44426128913627544,
        0.3809725441489958,
        0.3251319016777971,
        0.2649564261696582,
        0.21444088476073295,
        0.16310330111587365,
        0.11011853852133136,
        0.06499341940501024,
        0.026296397585253567,
        0.014955270570110998
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2847007 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847007; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015296232148357907,
        0.021583028773726233,
        0.0386309201206741,
        0.06421526185218372,
        0.07821683613703796,
        0.08698040082093231,
        0.129411132462969,
        0.2292567949428997,
        0.34716981728531054,
        0.4744412992310873,
        0.6350087653455014,
        0.8203915901857636,
        0.950756215211273,
        1,
        0.9801038423860567,
        0.914809306756183,
        0.8082537204861105,
        0.6507072163854885,
        0.4683380476409086,
        0.3038325687291953,
        0.1855353183185008,
        0.09867947286395855,
        0.059093426886551385,
        0.02958788650677712,
        0.006235609536611607,
        0.000008846353380936543,
        0.000040451516276566944,
        0.000026951598643768702,
        0.000011541850792779927,
        0.00005113577873184014,
        0.00014627213772217633
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Mamiya M18 / prf-solomatov-pred-mamiya-m18-39a4a51185f6@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.2847007 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.2847007; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04684566634363738,
        0.11412211139628389,
        0.27253013427785744,
        0.45623769102078077,
        0.597529194694639,
        0.7084098844857073,
        0.8003645582887573,
        0.8474949306411963,
        0.848020219128369,
        0.7472827077699493,
        0.5896804609191337,
        0.410473560479479,
        0.246364796433588,
        0.1288259143725323,
        0.07895846409931553,
        0.04651362992785055,
        0.037744708741495894,
        0.03853005805746175,
        0.03951336965451789,
        0.029095090036659554,
        0.0008617576282741843,
        0.000035282210405524125,
        0.00003534369954130777,
        0.0000020808800259360092,
        0.000011452859090265673,
        0.00005198493013891431,
        0.00001535806304656083,
        0.005493517227038782,
        0.0046823601065961555,
        0.00093162440415496,
        0.002438524949183476
      ],
      "range": 1
    }
  }
]
