    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 5 / prf-solomatov-pred-minolta-dimage-5-9e13d46bc735@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 5 / prf-solomatov-pred-minolta-dimage-5-9e13d46bc735@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517566471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27431023; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.011053165270212491,
        0.020930363975479736,
        0.03751899949539753,
        0.026545387069808295,
        0.05724819776300193,
        0.06786457548853031,
        0.06696829788539849,
        0.04885506294530645,
        0.03651303140122287,
        0.024221445647618068,
        0.013330330261470746,
        0.013568013779114825,
        0.024469674465911213,
        0.022557899863960597,
        0.012191542630265605,
        0.01531012023072629,
        0.05141493831116481,
        0.21296720370792932,
        0.44347123969317764,
        0.5612204696182672,
        0.5365479576414874,
        0.4780908988564863,
        0.40649766942176524,
        0.3471038395017898,
        0.29252850327756647,
        0.23993218683038597,
        0.1853722660631138,
        0.1265358644284862,
        0.07395250437905329,
        0.03013210943523768,
        0.02071332837797763
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 5 / prf-solomatov-pred-minolta-dimage-5-9e13d46bc735@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 5 / prf-solomatov-pred-minolta-dimage-5-9e13d46bc735@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517566471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27431023; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.01960388965442521,
        0.030943952266798927,
        0.05945126401141476,
        0.099370348114657,
        0.12786043212990833,
        0.1446161254074346,
        0.19293972058728828,
        0.2982601371028366,
        0.4153591279357925,
        0.5392130029461273,
        0.6880550798269536,
        0.8623872864747363,
        0.9732046856358444,
        1,
        0.9661467898887627,
        0.888224600830434,
        0.7790915768721318,
        0.6218014090975011,
        0.44814390286853506,
        0.30369470436224644,
        0.19816610801087028,
        0.12442830352107921,
        0.08229253084916346,
        0.04948146877119778,
        0.022389424853932718,
        0.0034149391366118573,
        1.04355385130805e-7,
        0.000009754332051913326,
        0.00006203979754000769,
        0.00002772275707532022,
        0.00012417547851361057
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 5 / prf-solomatov-pred-minolta-dimage-5-9e13d46bc735@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 5 / prf-solomatov-pred-minolta-dimage-5-9e13d46bc735@1 / ENERGY_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: energy_response; output values are relative photon-response shape derived by dividing source values by wavelength in nm; basis: The source quantity is not established; energy response is the explicit primary assumption, with a photon-response alternative for sensitivity comparison. Numeric values and profile naming cannot prove source units or optical scope. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.000517566471698 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27431023; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.05848864185633908,
        0.1470658699449747,
        0.3465515294923735,
        0.5827956950886983,
        0.7441662931982324,
        0.8492643116761146,
        0.9262925720205946,
        0.9450948037144784,
        0.9037688968374724,
        0.7690217966656488,
        0.5902895119879416,
        0.40597520966409056,
        0.24553381291068765,
        0.13443590492414373,
        0.08879781580795501,
        0.05504740095978856,
        0.04172805972534924,
        0.03736876731828316,
        0.029234875531380957,
        0.012411324486791,
        0.000008577362025470213,
        0.00002384967878205325,
        0.000004117353323267507,
        0.000015602355701252487,
        0.0000054064945577312235,
        0.000017473441938067993,
        0.00004069553105929912,
        0.0000011858131331215103,
        0.00036239775319138397,
        0.0004947256995657166,
        0.00032638297677987227
      ],
      "range": 1
    }
  }
]