[
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / red",
    "type": "OSC_SENSOR",
    "channel": "RED",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27580357 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27580357; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.008884541994869755,
        0.01855904330752499,
        0.025108300809884368,
        0.011361270631848603,
        0.040692925040818,
        0.05230273125181085,
        0.0543932988249572,
        0.04256780287506794,
        0.035194334141505135,
        0.027852941497457772,
        0.01904225750232312,
        0.01983738861683335,
        0.030778401454339403,
        0.03241754267357743,
        0.024095516965208248,
        0.03146406698071384,
        0.0794786485178564,
        0.24879750468784723,
        0.4920683949087388,
        0.6282312444324053,
        0.617535407536603,
        0.5648933405756859,
        0.48477008473820704,
        0.4213926962584277,
        0.3567833077722671,
        0.2949838901650185,
        0.23405017926345187,
        0.16187669361930304,
        0.09785700018313759,
        0.03849874387050175,
        0.024771242083632204
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / green",
    "type": "OSC_SENSOR",
    "channel": "GREEN",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27580357 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27580357; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.015963741876147578,
        0.02405029782609413,
        0.047201220056723704,
        0.07840356816266011,
        0.10441588917793922,
        0.12267408286266926,
        0.16785206950004308,
        0.26875319271610587,
        0.39063413863714674,
        0.5186093494003722,
        0.6708989299884697,
        0.844684171419536,
        0.9625351114925742,
        1,
        0.9771998237731296,
        0.9122885900280405,
        0.8115052680427596,
        0.6590792135141689,
        0.4906304874878885,
        0.34123445175129535,
        0.22587528508061008,
        0.14043526340141282,
        0.0949328901000085,
        0.05771515575378521,
        0.028661431032237908,
        0.007148276942173012,
        0.00003485901578431345,
        0.000026951158028882657,
        0.000010860409094777127,
        0.0015827492733324663,
        0.00008855480007020939
      ],
      "range": 1
    }
  },
  {
    "model": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION",
    "name": "ESTIMATED PHOTON-RESPONSE MODEL / Minolta DiMAGE 7 / prf-solomatov-pred-minolta-dimage-7-fc7c31317c0f@1 / PHOTON_RESPONSE-SOURCE ASSUMPTION / blue",
    "type": "OSC_SENSOR",
    "channel": "BLUE",
    "dataQualityMarker": 1,
    "dataSource": "ESTIMATED relative photon-response effective camera detection model; not measured sensor QE or absolute efficiency. Assumed source quantity: photon_response; output values are relative photon-response shape retained from the photon-response source shape; basis: Alternative photon-response source-quantity assumption applied to the same numeric samples; this is a sensitivity comparison, not a probability or claim that the source measured this quantity. Original source unit=unknown, scale=unknown, scope=unknown; measurement method=unknown; source=Solomatov; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera'; src-solomatov-predictions-official-2026-09-13; Solomatov & Akkaynak, ICCP 2023, 'Spectral Sensitivity Estimation Without a Camera', data/predictions/.; https://github.com/COLOR-Lab-Eilat/Spectral-sensitivity-estimation Interchannel scale comparability=unknown; channel ratios inherit original possibly incomparable scales; shared normalization preserves input ratios, which may inherit incomparable source scales. Retained channel wavelength intervals (nm)=red:400-700,green:400-700,blue:400-700. Interpretation RMS is a sampled-assumption difference only, not uncertainty bounds; it excludes optics, gain and measurement-error uncertainty. Optical transmission is not separated; camera modification/filter configuration unknown. is_dslr=false means no additional DSLR LPF model was applied, not that the camera is unmodified. Method camera-spectra-siril-estimate-v1; stable wavelength sort; duplicate groups merged by median=0; identical duplicates removed=0; negative values floored=0 (total magnitude 0); bounded null interpolation=0; trimmed/omitted null samples=0; documented-gap samples omitted=0; partial channels=none. Shared normalization divisor=0.27580357 across all channels; uncertainty=unknown; no absolute QE inferred. Original positive peak=0.27580357; input scale hint=normalized_or_fractional (ambiguous, not proof of units).",
    "manufacturer": "Camera Spectra estimate",
    "version": 1,
    "is_dslr": false,
    "wavelength": {
      "value": [
        400,
        410,
        420,
        430,
        440,
        450,
        460,
        470,
        480,
        490,
        500,
        510,
        520,
        530,
        540,
        550,
        560,
        570,
        580,
        590,
        600,
        610,
        620,
        630,
        640,
        650,
        660,
        670,
        680,
        690,
        700
      ],
      "units": "nm"
    },
    "values": {
      "value": [
        0.04643359583779137,
        0.11480530146872282,
        0.2736981830945843,
        0.4605447275392411,
        0.6008752170974437,
        0.7014598832060078,
        0.7830736926284166,
        0.8092811126411452,
        0.7856880895341565,
        0.6832712136394754,
        0.5341231079786241,
        0.37886389940492793,
        0.23901677559866247,
        0.1411581438195307,
        0.09961845671540799,
        0.07012275801941215,
        0.058121611696324314,
        0.04963156930854811,
        0.037451701586023706,
        0.019038433766466474,
        0.000007884616939512422,
        0.0000057768791752768104,
        0.00001314729464886912,
        0.000029095199891720037,
        0.000003910516096655312,
        0.000003669172230076645,
        0.00003122467196490604,
        0.000007423403910253954,
        0.00008479777473511311,
        0.0004786401785879712,
        0.00109604966317151
      ],
      "range": 1
    }
  }
]
